4. Marking, test certificate, and standards
Note:
Full information in "user manual"
ATEX Zone 2 and 22
II 3G Ex ic IIC T5 Gc
II 3D Ex ic IIIB T100°C Dc
-10 °C ≤ Ta ≤ +50 °C
IECEx Zone 2 and Zone 22
Ex ic IIC T5 Gc
Ex ic IIIB T100°C Dc
-10 °C ≤ Ta ≤ +50 °C
CSA Class I Division 2
Class I Div. 2
Groups A, B, C and D T6
X - marking (special conditions of use for secure operation
within the potentially explosive atmosphere)
The ambient temperature range is -10 °C bis +50 °C.
The device must be protected from impact with high impact
energy, from intense UV-irradiation, and strongly charge
generating processes.
It is not allowed to use connectors inside the potentially
explosive atmosphere.
It is not allowed to remove, change and/or charge the
battery inside the potentially explosive atmosphere.
Warnings
The warnings on the product and on the battery must always
be observed!
Additional safety instructions for use in potentially explosive
atmospheres, see user manual.
Subject to technical changes.
06/2016
7" Industry Tablet
Type B7-A23.-2.../........
- Lumen X7
EPS 16 ATEX 1 037X
IECEx EPS 15.0053X
E321557 Vol 5 sec 1
EN 4/12