4.1.2.1
Recurring welding tasks (JOB 1–7)
The user has 7 more memory locations at their disposal to save recurring or different welding tasks on a
permanent basis. To do so, simply select the required memory location (JOB 1–7) and the welding task is
set as described previously.
The three rotary knobs for AC frequency, AC balance and the tungsten electrode diameter are
exceptions. These settings are made in the operation sequence (signal lights with same name).
Switching a JOB is only possible if no welding current flows. Up-slope and down-slope times can be set
individually for latched and non-latched operation.
Selection
When one or more of the recurring welding tasks (JOB 1–7) has been selected the JOB signal light
comes on.
099-00T400-EW501
21.10.2016
Figure 4-2
Welding procedure
TIG welding
17