Troubleshooting
Problem
Problems in monitoring
heart rate with the
chest band
Cause
Remedy
Other transmitters situated nearby.
Move the equipment far enough away to stop signal interference (minimum distance between
two units 80 cm).
Strong interference sources nearby.
Find the interference source (e.g. an electrical domestic appliance) and move it away, or move
the equipment.
Worn heart rate monitor chest band.
Change the chest band.
Chest band transmitter not making proper skin contact.
Dampen the inside of the chest band with water.
Control panel not working properly.
Contact the Technogym Technical Support Service.
Damaged transmitter.
Change the chest band.