AC PARAllEl OPERATION APPlICATIONS

TIP:
• Make sure that it is in good working order. A faulty appliance or
power cord can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance
and determine whether the problem is the appliance, or the rated
load capacity of the generator has been exceeded.
• Make sure that the combined electrical rating of the tools or
appliance does not exceed that of the generator.
• Never connect different generator models.
• Don't remove the parallel operation cable when the generator
operation.
• For single generator operation, the parallel operation cable must be
removed.
• Substantial overloading that continuously lights the overload
indicator (red) may damage the generator Marginal overloading
that temporarily light the overload indicator (red) may shorten the
service life of the generator.
• For continuous operation, do not exceed the rated power.
• Rated power in parallel operation is: 6KW.
WARNING
operation
21