Advertisement

Operation MANUAL
Inverter
JIN3500E
®Registered trademark of JET Equipment & Tools Ltd.
Important Safety Instructions
Save These Instructions
www.jetgroupbrands.com
M14-IPEWASH

Advertisement

Table of Contents
loading

Summary of Contents for Jet JIN3500E

  • Page 1 Operation MANUAL Inverter • JIN3500E Important Safety Instructions Save These Instructions ®Registered trademark of JET Equipment & Tools Ltd. M14-IPEWASH www.jetgroupbrands.com...
  • Page 2: Table Of Contents

    table of contents Safety Introduction Safety Warnings Safety Information Control Function Description Control Panel 10 3 in 1 Switch Knob 10 Engine Smart Control 11 Digital Display Meter 11 Oil Warning Light 12 Overload Indicator Light (Red) 12 AC Pilot Light (Green) 13 DC Protector 13 Ground (Earth) Terminal 13 Parallel Operation Outlets...
  • Page 3 table of contents Maintenance 24 Maintenance 24 Maintenance Chart 26 Spark Plug Inspection 26 Carburetor Adjustment 27 Clean Fuel Filter 27 Engine Oil Replacement 28 Air Filter 28 Muffler Screen Storage 30 Drain the Fuel 30 Engine Troubleshooting 31 Engine Can’t Start 31 Generator Won’t Produce Power Parameters 32 Parameters...
  • Page 4: Introduction

    introduction Attention: Read through the complete manual prior to the initial use of your generator. Using the Operator’s manual The operating manual is an important part of your generator and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being ad- dressed.
  • Page 5: Safety Warnings

    safety Save these Instructions SAFETy WARNINGS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards.
  • Page 6: Safety Information

    safety SAFETy INFORMATION Read and understand this owner’s manual before operating your generator. It will help you avoid accidents if you get familiar with your generator’s safe operation procedures. DANGER Do not use indoors. DANGER Keep the machine clean and avoid spilling combus- tibles including gasoline on it.
  • Page 7 safety CONNECTION TO A HOME POWER SUPPly If the generator is to be used as standby home power supply the connection is to be performed by a qualified electrician. When loads are connected to the generator, carefully check whether electrical connections are safe and reliable.
  • Page 8 safety UNIT SAFETy SyMbOlS There is the warning label on the machine to remind you of the safety regulations. SyMbOlS Read the safety instructions before using the generator. Only fill the generator in well-ventilated areas and keep it away from open flames sparks and cigarettes Spilled fuel should be soaked up immediately.
  • Page 9: Control Function

    control function Control Function DESCRIPTION 1. Fuel tank cap 2. Handle 3. Control panel 4. Inverter parts 5. Battery 6. Brake 7. Recoil starter grip 8. Shutter 9. Muffler 10. Oil drain bolt 11. Oil filler cap 12. Air cleaner 13. Carburetor 14. Spark plug 15. Left cover...
  • Page 10: Engine Smart Control

    control function 3 IN 1 SWITCH kNOb 1. Engine/fuel valve OFF”; Ignition circuit is switched off. Fuel is switched off. The engine will not run. 2. Engine switch\fuel valve choke. “ON” Ignition circuit is switched on. Fuel is switched on. Choke is switched on.
  • Page 11: Digital Display Meter

    control function DIGITAl DISPlAy METER liquid crystal display Normal Operation: During the normal operation, the operation key (3) for switching the display cycle showing: voltage current power- accumulative time current time. 1. Multimeter 2. Liquid crystal display In case of failed operation: 3.
  • Page 12: Overload Indicator Light (Red)

    control function OvERlOAD INDICATOR lIGHT (RED) The overload indicator light comes on when an overload of a connected electrical device is detected, the inverter control unit overheats, or the AC output voltage rises. Then, the AC protector will trip, stopping power generation in order to protect the generator and any connected electric devices.
  • Page 13: Dc Protector

    control function DC PROTECTOR The DC protector turns to “OFF” automatically when electric device being connected to the generator is operating and current above the rated flows. To use this equipment again, turn on DC protector by pressing its button to “ON”. 1.
  • Page 14: Pre-Operation

    operation Pre-Operation NOTICE • Pre-operation checks should be made each time operation. WARNING • The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair. FUEl WARNING •...
  • Page 15: Engine Oil

    operation ENGINE OIl The generator has been shipped without engine oil. Do not start the engine until filled with the sufficient engine oil. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. Recommended engine oil: SAE 10W -30 Recommended engine oil grade: API Service SE type or higher...
  • Page 16: Operation

    operation Operation NOTICE • Never operate the engine in a closed area or it may cause un- consciousness and death within a short time. Operate the engine in a well ventilated area. The generator has been shipped without engine oil. Do not start the engine until filled with the sufficient engine oil.
  • Page 17 operation Electric Start Turn the engine switch on the control panel to ON Or press it to START if it is electrical start state then generator unit can be started In order to extend the service life of the storage battery do not press on the switch for more than 3 seconds and the interval between two pressings should be longer than 10...
  • Page 18: Alternating Current (Ac) Connection

    operation TIP: Turn off any electric devices. 1. Disconnect any electric devices. 2. Turn the ESC to “OFF” (1). 3. Turn the 3 in 1 switch to “OFF” (2). a. Ignition circuit is switched off. b. Fuel valve is switched off. AlTERNATING CURRENT (AC) CONNECTION WARNING •...
  • Page 19: Battery Charging

    operation • If the generator is connected to multiple loads or electricity consumers, please remember to first connect the one with the highest starting current. And last connect the one with the lowest starting current. • If the generator is overloaded, or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and after about 4 seconds, the connected appliance(s) will shut off, and the output indicator (green) will go OFF. Stop both engines and investigate the problem. Determine if the cause is a short circuit in a connected appliance or an overload, correct the problem and restart the generator. bATTERy CHARGING TIP: • The generator DC rated voltage is 12V. • Start the engine first, and then connect the generator to the battery for charging. • Before starting to charge the battery, make sure that the DC protector is turned on.
  • Page 20: Ac Parallel Operation

    operation TIP: • Follow instructions in the owners manual for the battery to determine the end of battery charging. • Measure the specific gravity of electrolyte to determine if the battery is fully charged. At full charge, the electrolyte specific gravity is between 1.26 and 1.28.
  • Page 21: Ac Parallel Operation Applications

    operation AC PARAllEl OPERATION APPlICATIONS TIP: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 22: Application Range

    operation APPlICATION RANGE When using the generator, make sure the total load is within rated output of a generator. Otherwise, generator damage may occur. Power 0.8-0.95 0.4-0.75 Factor (Efficiency 0.85) BC3500IG ~3,000W ~2,400W ~1,200W Rated voltage 12V Rated current 8A TIP: •...
  • Page 23 operation NOTICE • Do not overload. The total load of all electrical appliances must not exceed the supply range of the generator. Overloading will damage the generator. • When supplying precision equipment, electronic controllers, PCs, electronic computers, microcomputer based equipment or battery chargers, keep the generator a sufficient distance away to prevent electrical interference from the engine.
  • Page 24: Maintenance

    maintenance Maintenance Safety is an obligation of the owner. Periodic inspection, adjustment and lubrication will keep your generator in the safest and most efficient condition possible. The most important points of generator inspection and lubrication are explained on the following pages. WARNING •...
  • Page 25 maintenance Item Routine Pre-operation 6 Months / 100 12 Months / check (daily) Hours 300 Hours Check hose weather for cracks Crankcase or damage. breather hose Replace if necessary. Decarbonizes cylinder head. Cylinder head More frequently if necessary. Check and adjust Valve when engine is clearance...
  • Page 26: Spark Plug Inspection

    maintenance SPARk PlUG INSPECTION The spark plug is important engine components, which should be checked periodically. 1. Unscrew and take off the left exterior cover. 2. Remove the noise suppressor cap assy install spark plug box wrench on the spark plug appropriately. 3.
  • Page 27: Clean Fuel Filter

    3. Put the fuel filter (5) into noncombustible or higher flash point solvent and clean it. 4. Assemble fuel filter to the main jet (6) on the fuel tank then install tube clip. ENGINE OIl REPlACEMENT Avoid draining the engine oil immediately after stopping the engine.
  • Page 28: Air Filter

    maintenance NOTICE • Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. Don’t allow foreign ob- jects to fall into engine. • Oil and gasoline could pollute the environment, don’t throw it in the trash or pour it on the ground.
  • Page 29 maintenance 1. Unscrew 6 bolts (1) and take off shutter (2). 2. Remove the muffler screen (4,5), and remove the bolt (3). 3. Clean the carbon on the muffler screen with a wire brush. 4. Check the muffler screen and spark ar- rester, replace if it damaged.
  • Page 30: Storage

    storage Storage Long term storage of your machine will require some preventive procedures to guard against deterioration. DRAIN THE FUEl 1. Turn the 3 in 1 switch to “OFF”. 2. Remove the fuel tank cap, remove the filter. Extract the fuel from the fuel tank into an approved gasoline container using a commercially available hand siphon.
  • Page 31: Engine

    troubleshooting ENGINE Perform the following steps to protect the cylinder, piston ring, etc. from corrosion. 1. Remove the spark plug; pour about one table-spoon of SAE 10W- 30 into the spark plug hole and reinstall the spark plug. 2. Recoil start the engine by turning over several times (with 3 in 1 switch knob off) to coat the cylinder walls with oil.
  • Page 32: Parameters

    Parameters Item JIN3500E Generator Type Inverter Rated frequency (Hz)* Rated voltage (v)* Rated output power (kW) Max output power (kW) Generator Power Factor AC output quality ISO8528 G2 THD/% <5 Noise Level dB/LpA/ LwA/K 4m (1/4 load) DC Output/ V-A...
  • Page 33: Wiring Diagram

    wiring diagram Wiring Diagram 120v...