DC PROTECTOR

• Reduce the load of the connected electric device below the speci-
fied rated output of the generator if the DC protector turns off. If
the DC protector turns off again, stop using the device immedi-
ately and consult a franchised dealer.

GROUND (EARTH) TERMINAl

PARAllEl OPERATION OUTlETS

bRAkE

control function
The DC protector turns to "OFF"
automatically when electric device being
connected to the generator is operating and
current above the rated flows. To use this
equipment again, turn on DC protector by
pressing its button to "ON".
1. "ON" Direct current is output.
2. "OFF" Direct current is not output.
NOTICE
Ground (Earth) terminal (1) connects the
earth line for prevention of electric shock.
When the electric device is earthed, always
the generator must be earthed.
This is the terminal for connecting special
cables for parallel running of two generator.
The parallel running requires two generator
and the special cables. (The rated output
in parallel running is 6.0Kva and the rated
current is 60A/100V;50A/120V;26A/230V.)
The handing, operation procedure and
the notes on usage are described in the
PARALLEL RUNNING KIT OWNER'S
MANUAL included in the Parallel.
During the operation and idle period of
machine, brake timely and switch to "STOP".
In case of the machine is required to be
moved, switch the brake to "RUN".