Service Diagnostics and Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. After servicing, reconnect electrical power and gas supply. Before placing appliance into
operation, always check for gas leaks with soapy water solution. DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.

Micro Switch

To access Micro Switch:
1. Remove main top (see Main Top Access section,
page 16).
2. Remove wiring connectors from micro switch.
Micro Switch
3. Push clips outward to disengage micro switch.
Clip
© 2011 Viking Preferred Service
WARNING
Connectors
3. Remove micro switch from gas tap assembly.
Micro Switch
4. Repair/replace micro switch as necessary.
5. Reverse procedure to reinstall
20