1.11 WIRING DIAGRAM MEC 25
[b]
1
[n]
Ef2
2
[m]
3
M1
L N
1a
N
J1
J2
L N
SB RS
NC
P
L
J22
N
J21
SB
J20
RS
J19
J18
Op
Ac
= Control equipment
Br1
= Burner
Br2
= Second burner (MEC 85)
C1
= Fan motor condenser
C2
= Flue exhaust motor condenser (MEC 85)
Cs
= Printed circuit board
Ea1
= Ignition electrode
Ea2
= Br2 ignition electrode (MEC 85)
Ef1
= Flue exhaust motor (MEC 25-57)
Ef2
= Flue exhaust motor (MEC 85)
Er
= Flame detection electrode
Ev
= Gas solenoid valve
Fr
= Radio interference filter
M1
= Ef2 connection terminal boards (MEC 85)
Mvc1
= Centrifugal fan motor (MEC C 25-85)
Mvc2
= Centrifugal fan motor (MEC C 50-85)
Mvc3
= Centrifugal fan motor (MEC C 85)
Mve1
= Axial fan motor (MEC 25-85)
Mve2
= Axial fan motor (MEC 50-85)
Mve3
= Axial fan motor (MEC 85)
C2
1a N
N 1a
N 1a
J4
J3
Tr
Ts1
NO
Ef1
C
Ts2
Ev
T v
K3
K1
K2
R3
R1
2
1
Sb
Rs
3
N
L
[g/ v]
[b]
[m]
[ n]
J27
J26 J25
ELECTRICAL SCHEMA FOR AXIAL FAN
Er
Ea2
Ea1
Br2
Br1
common
J23
J25
C1
condenser
[m]
J26
J24
Mve1
max.
J27
R2
J28
J29
Cable colors
J30
J31
J32
J33
J34
J35
J36
3 (U)
N
L
1 (U)
Cs
Op
= Jumper for auxiliaries
P
= Differential pressure switch
R1
= Fan relay (MEC C)
R2-R3 = Fan relay (MEC C / MEC 85)
Rs
= Reset button
Sb
= Lockout signal
Tr
= Br2 ignition transformer (MEC 85)
Ts1
= Safety thermostat
Ts2
= Second safety thermostat (MEC 85)
Tv
= Fan thermostat
ATr
= Autotransformer
= Fuse
- - - - - = Connection to be made
= Series connection
= Varying connection (model depending)
Warning:
- Install an omnipolar switch with a contact opening of at
least 3 mm.
- The 230 V ~ 50 Hz single-phase power supply must be
connected according to the phase-neutral polarity.
page 17
Ac
ATr
L M M 1 2 3 4 5 6
[n]
[b]
[b]
= blue
[bi]
= white
[g]
= yellow
[g/v] = yellow/green
[gr]
= grey
[m]
= brown
[n]
= black
Fr
230 V ~
(4)
N
50 Hz
L
(2)