Digital Quick-Response Thermometer
GTH 1170
Operating Manual
WEEE-Reg.-Nr. DE93889386
GHM Messtechnik GmbH • Standort Greisinger
Hans-Sachs-Str. 26 • D-93128 Regenstauf
+49 (0) 9402 / 9383-0
+49 (0) 9402 / 9383-33
info@greisinger.de

Advertisement

loading

Summary of Contents for GREISINGER gth 1170

  • Page 1 H56.0.01.6C-06 Digital Quick-Response Thermometer GTH 1170 Operating Manual WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH • Standort Greisinger Hans-Sachs-Str. 26 • D-93128 Regenstauf    +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de...
  • Page 2 H56.0.01.6C-06 Operating Manual GTH 1170 Page 2 of 6 CONTENTS GENERAL NOTE ..........................2 SAFETY ............................3 ..........................3 NTENDED ......................3 AFETY SIGNS AND SYMBOLS ........................3 AFETY GUIDELINES PRODUCT SPECIFICATION ......................4 ......................... 4 COPE OF SUPPLY ................... 4 PERATION AND MAINTENANCE ADVICE NOTES TO FUNCTIONS OF DEVICE .....................
  • Page 3: Safety

    H56.0.01.6C-06 Operating Manual GTH 1170 Page 3 of 6 2 Safety 2.1 Intended Use The safety requirements (see below) have to be observed. The device must be used only according to its intended purpose and under suitable conditions. Use the device carefully and according to its technical data (do not throw it, strike it, …) Protect the device from dirt.
  • Page 4: Product Specification

    H56.0.01.6C-06 Operating Manual GTH 1170 Page 4 of 6 Product Specification 3.1 Scope of supply The scope of supply includes: Device GTH1170, incl. 9V battery block Operating Manual 3.2 Operation and maintenance advice • Battery operation: If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced. However, the device will operate correctly for a certain time.
  • Page 5: Configuration Of The Instrument

    H56.0.01.6C-06 Operating Manual GTH 1170 Page 5 of 6 To adjust a measuring offset and scale proceed like follows: 1. Switch off the instrument. 2. Press the ‘Hold‘ key while switching on the instrument. Keep ‘Hold‘ key pressed until ‘OFS‘ appears in the display (about 3 seconds).
  • Page 6: System Messages

    H56.0.01.6C-06 Operating Manual GTH 1170 Page 6 of 6 System Messages: Er. 1 = measuring range has been exceeded Er. 2 = meas. values have fallen below perm. range Er. 7 = System fault - the device has detected a system fault (defective or far outside allowable ambi-...