Manual for connection and operation of the GIR 230 TC
Page 1 of 14
Manual for connection and operation of
GIR 230 TC
Version 1.1

Advertisement

Table of Contents
loading

Summary of Contents for GREISINGER GIR 230 TC

  • Page 1 E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 1 of 14 Manual for connection and operation of GIR 230 TC Version 1.1...
  • Page 2: Table Of Contents

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 2 of 14 Index 1. SAFETY REGULATIONS ............................3 2. INTRODUCTION ................................ 4 3. ELECTRICAL CONNECTION..........................4 3.1. Terminal assignment..............................4 3.2. Connection data ............................... 4 3.3. Connecting an input signal............................5 3.3.1.
  • Page 3: Safety Regulations

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 3 of 14 1. Safety regulations This device was designed and tested considering the safety regulations for electronic measuring devices. Faultless operation and reliability in operation of the measuring device can only be assured if the General Safety Measures and the devices specific safety regulations mentioned in this users manual are considered.
  • Page 4: Introduction

    Page 4 of 14 2. Introduction The GIR 230 TC is a universal, microprocessor controlled displaying -, monitoring- and controlling device. The device is supporting one interface for the connection of: - Thermocouple probes type K, J, N, T and S...
  • Page 5: Connecting An Input Signal

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 5 of 14 3.3. Connecting an input signal Please take care not to exceed the limitations of the inputs when connecting the device as this may lead to destruction of the device.
  • Page 6: Configration Of The Device

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 6 of 14 4. Configration of the device Please note: When you are configuring the device and don’t press any button for more than 60 sec. the configuration of the device will be cancelled. The changes you made will not be saved and will be lost! Hint: The buttons 2 and 3 are featured with a ‘roll-function‘.
  • Page 7: Scaling Of The Standard Signal 0-50Mv

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 7 of 14 4.2. Scaling of the standard signal 0-50mV This chapter describes how to configure the device for using the 0-50mV standard signal as desired input signal. This instruction demands that you selected “0.050“ as your desired input signal. The display has to show “InP“.
  • Page 8: Selecting The Output Function

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 8 of 14 4.3. Selecting the output function The display shows “outP“. (output) Use button 2 and button 3 (middle and right button) to select the desired output-function.
  • Page 9: Switchpoints And Alarm-Boundaries

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 9 of 14 5. Switchpoints and alarm-boundaries Please note: The settings of the switchpoints will be cancelled, when no button was pressed for more than 60 sec. changes you may have made already won‘t be saved and will be lost! Hint: The buttons 2 and 3 are featured with a ‘roll-function‘.
  • Page 10: 2-Point-Controller With Alarm Function, 3-Point-Controller With Alarm Function

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 10 of 14 Press button 1 to validate your selection. The display shows “2.off“again. Now you finished configuring your device. Press button 1 to switch over to display the measuring value.
  • Page 11: Minimum/Maximum-Alarm

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 11 of 14 5.3. Minimum/maximum-alarm This chapter describes how to configure the device‘s alarm boundaries for min-/max-alarm-monitoring. This instruction demands that you selected “AL“ as your desired output function.
  • Page 12: Offset- And Slope-Adjustment

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 12 of 14 6. Offset- and slope-adjustment The offset and slope-adjustment function can be used for compensating the tolerance of the used sensor, or for vernier adjustment of the used transducer or transmitter.
  • Page 13: Error Codes

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 13 of 14 8. Error codes When detecting an operating state which is not permissible, the device will display an error code. The following error codes are defined: Err.1:...
  • Page 14: Specification

    E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 14 of 14 9. Specification Absolute maximum ratings: Performance data Limit values Connection Notes between min. max. min. max. 207 V 244 V 253 V Supply voltage 3 and 4...