GREISINGER GTH 200 air Operating Manual

GREISINGER GTH 200 air Operating Manual

Fast precision air thermometer

Advertisement

Quick Links

H62.0.31.6C-02
as of version 2.1
Please carefully read these instructions before use!
Please consider the safety instructions!
Please keep for future reference!
GREISINGER
D - 93128 Regenstauf, Hans-Sachs-Straße 26
+49 (0) 9402 / 9383-0
Fast precision air thermometer
GTH 200 air
electronic GmbH
+49 (0) 9402 / 9383-33
Operating manual
WEEE-Reg.-Nr. DE 93889386
info@greisinger.de

Advertisement

Table of Contents
loading

Summary of Contents for GREISINGER GTH 200 air

  • Page 1 H62.0.31.6C-02 Operating manual Fast precision air thermometer GTH 200 air as of version 2.1  Please carefully read these instructions before use!  Please consider the safety instructions!  Please keep for future reference! WEEE-Reg.-Nr. DE 93889386 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26...
  • Page 2: Table Of Contents

    2 Safety 2.1 Intended use The GTH 200 air measures the temperature of ambient air. The measurements uses a Pt1000 precision sensor located in the probe tube and has to be protected from any dirt. The open probe design and the precise sensor ensures fastest temperature measurements.
  • Page 3: Safety Signs And Symbols

    This device must not be used at potentially explosive areas! The usage of this device at potentially explosive areas increases danger of deflagration, explosion or fire due to sparking. 2.4 Scope of supply The scope of supply includes: Handheld measuring device GTH 200 air 9V battery Operating manual...
  • Page 4: Operation And Maintenance Advice

    H62.0.31.6C-02 Operating manual GTH 200 air page 4 of 8 _____________________________________________________ _____________________________________________________________________________ 2.1 Operation and maintenance advice a.) Battery operation: If BAT is shown in the left part of the display the battery has been used up and needs to be replaced.
  • Page 5: Display Of Min-/Max- Value Memory

    H62.0.31.6C-02 Operating manual GTH 200 air page 5 of 8 _____________________________________________________ _____________________________________________________________________________ 3.5 Display of min-/max- value memory For all measuring values the lowest and highest measured value since the switch-on of the device will be stored. display switching between „Lo‟ and MIN value...
  • Page 6: Offset- (Zero Point) And Slope Adjustment

    H62.0.31.6C-02 Operating manual GTH 200 air page 6 of 8 _____________________________________________________ _____________________________________________________________________________ 5 Offset- (Zero point) and Slope Adjustment The temperature measuring value can be readjusted by the following settings. However, please consider that the integrated sensors are very precise and readjustment is very rarely needed.
  • Page 7: Specification

    H62.0.31.6C-02 Operating manual GTH 200 air page 7 of 8 _____________________________________________________ _____________________________________________________________________________ 7.2 Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points. The device must not be disposed in the unsorted municipal waste! Send the device directly to us (sufficiently stamped), if it should be disposed.
  • Page 8 H62.0.31.6C-02 Operating manual GTH 200 air page 8 of 8 _____________________________________________________ _____________________________________________________________________________...

Table of Contents