Soft Dry Mode Operation - Panasonic CS-PW18CKE Service Manual

Table of Contents

Advertisement

CS-PW18CKE CU-PW18CKE
8.3.

Soft Dry Mode Operation

• • • • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
• • • • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
• • • • Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6
minutes.
Time Delay Safety Control
• • • • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Anti-Freezing Control
• • • • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Compressor Reverse Rotation Protection Control
• • • • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Anti-Dew Formation Control
• • • • Same as Anti-Dew Formation Control for Cooling Mode operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
• • • • Fan speed off and on at Lo- speed.
• • • • Deodorizing Control.