Volume
mfx protocol: The total volume for the sound functions can be changed easily with the 60213/60214/60215 Central Station in the CV
menu "Sound". The function mapping (assigning the function buttons) and the individual volume settings are done with the function
buttons. The sound number is required for the function mapping.
fx protocol: In the fx protocol only the total volume can be changed with CV 63. It is not possible to change the individual volumes.
However, settings done under mfx are preserved.
DCC protocol: To change the individual sound volume must be 31 CV changed to the value 16 and CV 32 to 0 before. The sound
number is required for the function mapping and for the assignment of the CVs to the sound.
Sound functions
Sound effect: Function f2
Sound effect: Function f3
Sound effect: Function f7
Sound effect: Function f10
Sound effect: Function f11
Sound effect: Function f12
Sound effect: Function f13
Sound effect: Function f14
Sound effect: Function f15
Total volume (CV63) and brake squeal (CV 146) see tables below.
CV
Steam
CV
300 Running sounds
300
301
1
301
303
3
302
309
9
309
302
2
303
304
4
304
310
10
307
314
14
314
305
5
305
Sound-Nr.
Diesel
CV
Running sounds
300
1
301
2
302
9
309
3
303
4
304
7
308
14
314
5
305
Default
Electric
Running sounds
180
1
180
2
180
9
180
3
180
4
180
8
180
14
180
5
180
Values
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
37