S1 DIP #1 ON- AUX 1 Controls Pool Cleaner
If you installed a booster pump for a pool cleaner,
the relay coil for the booster pump must be plugged
into the AUX 1 relay socket. If a non-booster
pump cleaner is installed, plug the JVA into the
cleaner JVA socket. Turn ON DIP Switch #1.
• Main filter pump turns on whenever cleaner
turns on.
• Cleaner will not turn on until filter pump
has been on for three (3) minutes (to ensure
priming of system).
• Cleaner turns off when water circulation is
to spa.
• Cleaner turns off when spa spillover feature
is activated.
• Cleaner turns off for three (3) minutes when
solar is activated (to ensure air is purged
from the system).
• AquaLink RS Control Panel display reads
"CLEANER" rather than "AUX 1".
S1 DIP #2 ON- AUX 2 Controls Low Speed of
Filter Pump
Turn this switch ON if you want to control both
speeds of a two-speed filter pump. With this switch
on, the filter pump button on the AquaLink RS
Control Panel will control high speed and the AUX
2 button will control low speed.
IMPORTANT
You must also install a Jandy Two-
Speed Relay.
S1 DIP #3 ON- AUX 3 Controls Spa Spillover
(Operates with Pool/Spa Combination)
Turn this switch ON, and when the AUX 3 button
on the AquaLink RS Control Panel (or Spa Side
Switch) is pressed, the Return Valve Actuator will
rotate to spa circulation. Because the Intake Valve
Actuator does not rotate, the spa will fill with water
and overflow into the pool.
NOTE Leave AUX 3 relay socket empty.
S1 DIP #4 ON- Heater Cool Down Disabled
Turn this switch ON to disable the heater cool
down safety feature on the AquaLink RS.
CAUTION
Turn this DIP Switch ON only if you are using
an electric heater or a heat pump that does
not retain residual heat. If you are turning this
switch ON for service purposes, be sure to turn
it back off.
S1 DIP #5 ON- Factory Use Only
This switch is used for calibration by Jandy
certified technicians only (will momentarily
display the solar temperature and if installed, actual
FlowLink water pressure). Please leave this switch
in the OFF position.
S1 DIP #6 ON
(Combo Systems, Pool and Spa)
Change Spare AUX to activate when Filter Pump is
on and system is in spa mode.
(Dual Equipment)
This switch only applies to DUAL EQUIPMENT
systems. When OFF a separate heater is used for
the pool and spa. When ON the pool and spa share
the same heater.
S1 DIP #7 ON- Not Used
(Dual Equipment)
Change air sensor to solar sensor - Air temperature
no longer displayed. Adjustable Freeze Kit must be
added for freeze protection.
S1 DIP #8 ON- Heat Pump Instead of Gas Heater
Turn this switch ON if you have installed a heat
pump instead of a gas heater. After thermostat
setting has been reached, heater will remain OFF
for 5 minutes.
S2 DIP #1 ON- Heat Pump Priority
This switch is used for configuring solar priority or
heat pump priority. Set this switch to ON if Heat
Pump Priority will be used. Set this switch to OFF
if Solar Priority is to be used.