Motorola MC919Z Integrator Manual Supplement page 72

Rfid mobile computer
Hide thumbs Also See for MC919Z:
Table of Contents

Advertisement

6 - 10 MC919Z Integrator Guide Supplement
Troubleshooting the Modem Module (Continued)
Table 6-9
Symptom
Dial-out fails
Possible Cause
Location setting is
incorrect.
Incorrect server phone
number.
Pulse dialing not
supported for country.
The Connection Manager
routes are incorrect.
Verify Dialing Locations. Verify Dialing Patterns are correct for the
current location. For example, enter 'G' in the For local calls, dial:
field to dial directly, or '9,G' if the telephone system requires dialing
'9' first to access an outside line.
Verify the connection phone number in the Connecting window.
Use a connection within a tone-dialing system.
Warm boot the MC919Z and confirm the connection settings.
Action