Invacare® SB®755

7.4 Environmental conditions

Storage and
transportation
Temperature
-10°C to +50°C
Relative humidity
Atmospheric
pressure
Be aware that when a bed has been stored under low
temperatures, it must be adjusted to operating conditions
before use.

7.5 Electrical system

Voltage
Uin 230 Voltage, AC, 50–60 Hz (AC = Alternating
supply
current)
Maximum
Iin max.1,5 Ampere
current
input
Intermit-
10 % 2 min ON / 18 min OFF
tent (peri-
odic motor
operation)
Insulation
CLASS II equipment
class

7.6 Electromagnetic compliance (EMC)

Guidance and manufacturer´s declaration – electromagnetic emission
The medical bed is intended for use in the electromagnetic environment specified below. The customer or the user of the bed should assure
that it is used in such an environment.
Emissions test
Compliance
RF emissions
Group I
CISPR 11(partly)
RF emissions
Class B
CISPR 11(partly)
Harmonic emissions
Class A
IEC 61000-3-2
Voltage fluctuations
/ flicker emissions
Complies
IEC 61000-3-3
Guidance and manufacturer´s declaration – electromagnetic immunity
The medical bed is intended for use in the electromagnetic environment specified below. The customer or the user of the bed should assure
that it is used in such an environment.
Immunity test
IEC 60601–1–2 test level
Electrostatic
± 6 kV contact
discharge (ESD)
± 8 kV air
IEC 61000-4-2
Electrostatic transient
± 2 kV for power supply
/ burst
lines
IEC 61000-4-4
± 1 kV for input/output lines
Surge
± 1 kV differential mode
IEC 61000-4-5
± 2 kV common mode
16
Operation
+5°C to +40°C
20% to 75%
800 hPa to 1060 hPa
Electromagnetic environment - guidance
The medical bed uses RF energy only for its internal function. Therefore, its RF emissions are
very low and are not likely to cause any interference in nearby electronic equipment.
The medical bed is suitable for use in all establishments including domestic establishments
and those directly connected to the public low-voltage power supply network that supplies
buildings used for domestic purposes.
Compliance level
± 6 kV contact
± 8 kV air
± 2 kV for power supply
lines
± 1 kV for input/output lines
± 1 kV differential mode
± 2 kV common mode
Type B
Applied Part complying with the specified
Applied
requirements for protection against electrical shock
Part
according to IEC60601-1.
Sound level
55 dB (A)
Degree of
The control unit, external power supply, motors
protection
and hand controls are protected according to IPx4,
IPx6 or IPx6w (depending on configuration). See
bed product label and label on each electric device
for correct IP class. The lowest IP-classification
decides the overall classification of the bed.
IPx4 - The system is protected against water
splashed from any direction.
IPx6 - The system is protected against water
projected from any direction (not high pressure).
IPx6w - The system is protected against high
pressurized water and steam projected from any
direction.
The bed has no isolator (main switch). If the bed needs to
be electrically disconnected, it has to be unplugged from the
mains socket.
Electromagnetic environment – guidance
Floors should be wood, concrete or ceramic tile. If
floors are covered with synthetic material, the relative
humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment.