HEAT GLO MEZZO1000-AUB Owner's Manual
Hide thumbs Also See for MEZZO1000-AUB:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
NOTE: NOT INTENDED FOR
FIREPLACE INSERT.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner's Manual • 2304-974 Rev. C • 3/16
Owner's Manual

Care and Operation

Ref No: GMK10222
AS4553:
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEZZO1000-AUB and is the answer not in the manual?

Questions and answers

Summary of Contents for HEAT GLO MEZZO1000-AUB

  • Page 1: Care And Operation

    DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. DO NOT MODIFY THIS APPLIANCE. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 2: Welcome

    SAI Global Certification Nº: DMS (mm) Type of Gas Model Number Serial Number xxxx-xxx Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 3: Table Of Contents

    C. Contact Information ......35  = Contains updated information. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 4: Limited Lifetime Warranty

    Exclusion, and Limitations listed Igniters, Electronic Components, and Glass 2 years Factory-installed blowers Molded refractory panels 3 years Firepots and burnpots 2000-645C (10-15) Page 1 of 3 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 5 HHT (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interrup- tions or fluctuations of electrical power supply to the appliance. 2000-645C (10-15) Page 2 of 3 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 6 277 Lord Street 10 Martin Avenue Richmond 3121 East Perth 6000 Arncliff 2205 (03) 9429-5573 (08) 9228-2600 (02) 9597-7222 2000-645C (10-15) Page 3 of 3 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 7: Product Specific Information

    NOTE: The gas control valve supplied with this product is approved for a maximum inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 8: Important Safety And Operating Information

    • Install a switch lock or a wall/remote control with child are contacting the top of the firebox. Call a qualified service protection lockout feature. technician to service the appliance. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 9: General Operating Parts

    30 degrees or more depending on the thermometer settings and material characteristics being measured. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 10 Increase “A” dimension. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Figure 3.4. Good Faith TV Guidelines Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 11: Before Lighting Appliance

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fireplace with fixed glass assembly removed. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 12: Lighting Instructions (Ipi)

    Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 13: Appliance Break-In

    NOTICE! Open windows for air circulation during fire- place break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 14: Operation During A Power Outage

    CONTROL CAVITY other auxiliary functions that require household 220/240 (Shown in gray) VAC power. BATTERY CONTROL TRAY MODULE 3.5 Control Cavity Location Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 15: Control Module Operation

    IntelliFire™ Plus remote control. Follow instructions servicing and/or resetting the control module in the event of included with the installed control. a control module LOCK-OUT. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 16: Installation Precautions

    To prevent unintended operation when not using your fire- for compliance could void the user’s authority to operate place for an extended period of time (summer months, the equipment. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 17 STANDBY mode. Press the ON/OFF button twice to switch to IDLE mode. Figure 3.10 Mounting Remote Control Housing Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 18 Menu Menu Use the UP and DOWN arrows to toggle through the menu functions and value selec- Select Select tions in the submenus. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 19: Adjusting Flame Height

    4 seconds to enable or disable the child lock feature. NOTICE: No functions will be usable until child lock feature is disabled. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 20: Power Outage

    At control module, turn off fireplace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 21: Maintenance And Service

    3. Assure proper left and right placement of glass and kept clean. engage all four spring latches. CAUTION! Risk of Burns! The fireplace should be turned off and cooled before servicing. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 22: Remote Control

    • Check that louvers are not blocked. intact. • Vacuum and dust surfaces. • Inspect draft shield to verify it is not damaged or missing. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 23: Maintenance Tasks: Qualified Service Technician

    • Remove all foreign objects. • Verify unobstructed air circulation. Figure 4.2 IPI Pilot Flame Patterns Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 24: Frequently Asked Questions And Troubleshooting

    Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatnglo.com to locate a dealer. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 25: Troubleshooting

    Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 26 Check to assure correct shutter setting for your model and gas type. C. Gas Type Assure correct fuel matches unit gas model and components. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 27: Reference Materials

    After a qualified service technician has installed the Heat-Zone Kit, follow the instruction supplied with the kit ® for operation. See your dealer if you have questions. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 28: Service Parts

    LED Light Assembly SRV2316-014 13.1 LED 12V Power Supply 2273-308 13.2 Cord Assembly 2101-084 13.3 AUX300CE 2166-340 Additional service part numbers on following page. 3/16 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 29 LED Light Assembly SRV2304-014 13.1 LED 12V Power Supply 2273-308 13.2 Cord Assembly 2101-084 13.3 AUX300CE 2166-340 Additional service part numbers on following page. 3/16 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 30 LED Light Assembly SRV2304-014 13.1 LED 12V Power Supply 2273-308 13.2 Cord Assembly 2101-084 13.3 AUX300CE 2166-340 Additional service part numbers on following page. 3/16 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 31 LED Light Assembly SRV2323-014 13.1 LED 12V Power Supply 2273-308 13.2 Cord Assembly 2101-084 13.3 AUX300CE 2166-340 Additional service part numbers on following page. 3/16 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 32 Battery Pack 4067-223 14.5 Module 2166-306 14.6 Wire Harness 2166-304 14.7 Junction Cord 2222-374 14.8 DC Regulator 2326-131 Additional service part numbers on following page. Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 33 MEZZO1000-AUB BGK-36 MEZZO1300-AUB BGK-48 Refractory Assembly, Black Glass BGK- LINEARST MEZZO1300ST-AUB MEZZO1600-AUB BGK-60 Remote RC300AU-HNG 2166-333 Touch Up Paint TUP-GBK-12 Vinyl Siding Shield TRAP-VSS Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 34 MEZZO1300ST-AUB ULPK-1600 MEZZO1600-AUB Pilot Ori ce, NG 593-528 Pilot Ori ce, BU 593-529 Pilot Ori ce, LP 593-527 Regulator, NG NGK-DXV-50 Regulator, LP LPK-DXV-50 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...
  • Page 35: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2016 Heat & Glo • MEZZO1000-AUB, MEZZO1300-AUB, MEZZO1300ST-AUB, MEZZO1600-AUB Owner’s Manual • 2304-974 Rev. C • 3/16...

This manual is also suitable for:

Mezzo1300-aubMezzo1300st-aubMezzo1600-aub

Table of Contents