Supply Width
Field Type
Fixed Data
Row
Column
7-2 Defining Constant Text Fields
The width of your loaded supply. Choices include 1.20, 1.50,
or 2.00 inches.
Choices include text, bar code, constant text, and line.
In situations where the same data appears on all labels, you
can enter the repetitive data as fixed data. The operator does
not enter the data. The maximum number of characters is 40;
however, each field has a maximum length defined, so the
fixed data must be below that maximum.
Fixed data is stored with the format and automatically
displayed with the prompt during data entry.
The horizontal line where printing begins. For monospaced
fonts, distance from the bottom of print area to the pivot point.
The pivot point varies depending on how text is justified.
For proportionally spaced fonts, distance
from the bottom of print area to baseline of
characters in field. The range is 0 – 365.
The vertical line where printing begins. Type
the column position for the field. The distance
from the left edge of the print area to the
pivot point is the column location. The
range is 0 – 183.
Baseline
Baseline