Marine Gasoline
Marine Gasoline
Freq.
Freq
Model
Hz
4EFCD
4EFCD
50
50
5ECD
5ECD
60
60
ECD
ECD
EFCD
6EFCD
6EFCD
50
50
7.3ECD
7.3ECD
60
60
* Use voltage/frequency parameters Uu07--Uu23 only with ADC application program version 1.20 or higher.
[ See Figure 4-19 for Ed settings with optional sender kits.
] See Figure 4-20 for Cn settings with optional digital gauges (gauges are available on selected models only).
Note: Replacement controllers from Kohler Aftermarket Parts are shipped with factory settings for the 8.5/12RES.
Note: Setting the Ec parameter automatically selects the Ed parameter for the standard data inputs for that engine.
If you change Ec, check the Ed setting.
Figure 4-18 Configuration Parameters
Model
5/7.3ECD
5/7.3ECD
4/6EFCD
GM45891-KA1 *
* OP and WT sender kits
Figure 4-19 Ed Settings with Optional Sender Kits
Gauge Kit
Gauge Description
None
—
GM32337-KP1 Remote Digital Gauge for
Marine
GM46035-KP1 Three-Inch Digital Gauge
GM50822-KP1 Two-Inch Digital Gauge
* For ADCs with removable power mode jumpers, refer to TT-1439 for power down information.
[ Smartcraftt settings for ADC code version 2.00 or higher only, for models 5/7.3ECD and 4/6EFCD.
] Smartcraftt settings for ADC code version 2.20 or higher only.
w Before ADC code version 3.20, the power-down time was 48 hours.
SmartCraftt is a trademark of Mercury Marine, a division of Brunswick Corporation.
Figure 4-20 Communication Parameter Cn Settings (optional gauges are available on selected models only)
42
Section 4 Controller
Voltage, Phases
230 V, 1 Ph, 2 W
115/230 V, 1 Ph, 3 W
115 V, 1 Ph, 2 W
120/240 V, 1 Ph, 3 W
120 V, 1 Ph, 3 W
120 V, 1 Ph, 2 W
230 V, 1 Ph, 2 W
115/230 V, 1 Ph, 3 W
115 V, 1 Ph, 2 W
120/240 V, 1 Ph, 3 W
120 V, 1 Ph, 3 W
120 V, 1 Ph, 2 W
Sender Kit
Ed
None
0
No Change
master switch in
Cn
Setting
Cn00
Cn01
g
g
Cn02
Cn03
Cn04
Cn05
Cn07
g
g
Cn08
Cn09
Volts,
Engine
Hz
Market
Type
Uu*
Uc
2
6
5
1
0
0
0
0
2
6
5
1
0
0
Power Down
Time (when
AUTO position)
Description
48 hours
No CAN communication (not for use with these models)
Never/None
3-inch J1939 gauge with no sleep mode
CAN communication (not for use with these models)
Smartcraftt 3-inch gauge for generator set #1 with ECM [
48 hours
Smartcraftt 3-inch gauge for generator set #2 with ECM [
48 hours
Smartcraftt 3-inch gauge for generator set #3 with ECM [
48 hours
Smartcraftt 3-inch gauge for generator set #4 with ECM [
48 hours
Smartcraftt 3-inch gauge for generator set #1 without ECM [
48 hours
(not for use with these models)
1 hour w
Smartcraftt 2-inch gauge for generator set #1 with ECM ]
1 hour w
Smartcraftt 2-inch gauge for generator set #1 without ECM ]
(not for use with these models)
Data
Battery
Inputs
CO
Voltage
Ec
Ed[
CO
4
4
0
0
1
1
CANbus
Comm.
Bt
Cn]
12
12
2 or 8]
2 or 8]
TP-6391 9/08