1 - SYMBOLS

In this document:
Safety
recommendations,
!
and recommendations are by a warning-
triangle symbol accompanied by bold text.

2 - SAFETY PRECAUTIONS

2.1 - Smell of flue gas

- Switch off the appliance.
- Open doors and windows.
- Immediately contact your installer or your after-
sales service.

2.2 - Explosive or inflammable materials

- Do not store or use any inflammables materials
(paper, thinners, paints, etc.) within vicinity of the
appliance.
- Respect the minimum distances regard to inflam-
mable materials and fire-proof materials (16 in-
ches (40.6 cm) from the appliance).

2.3 - Fitting, commissioning

- The installation, electrical connection and the first
start-up must be carried out by a qualified profes-
sional and authorised in accordance with the ap-
plicable regulations and rules of good practice.
Respect the electrical connection plan.
- Danger from electrical shock :
• Before installation: make sure the appliance is
turned-off at all points. Secure against involun-
tary re-triggering.
- The appliance must not operate without water.
- Carry out the checks listed in Section 3 - page 31
- chapter VI - COMMISSIONING before the first
start-up of the system.
- Only use approved fuels indicated on the data
plate.
- Flue system (air inlets, conduits, gaskets etc.)
must not be modified in any way and not da-
maged.
- Connect only one boiler to each venting system
or chimney flue.
- The venting system piping must not feed into
another air extraction duct.
- Do not route the venting system piping through or
inside another duct used for exhaust air or other
flue gases.

I - SAFETY PRECAUTIONS

warnings
- 4 -
- Chimney type system B
• Ventilation openings in doors, windows and
walls must not be sealed or restricted.
Intoxication Risk: An insufficient air intake
can cause the evacuation of dangerous
smokes.
• Ensure that no mechanical air-extraction
equipment draws air from the boiler room, e.g.
kitchen vent hood, clothes dryer, central va-
cuum system, etc.
• If draught-proof windows are installed, mea-
sures must be taken to ensure there is an ade-
quate supply of air to the appliance for
combustion.
- Flue type system (C
• The flue type system (sealed) can be installed
in premises with or without a window or venti-
lation.
• Room sealed installation in a small room or
cupboard, make sure required clearances for
service are fulfilled.

2.4 - Servicing

- Recommendations for the user:
• take out an inspection/maintenance contract
with an competent and qualified engineer.
• have the appliance serviced at regular inter-
vals (annually).
- Respect
the
safety
chapter VII - MAINTENANCE - page 35.
- Only use original spare parts.

2.5 - Combustion air/Ambient air

- To avoid any corrosion, the combustion/ambient
air must be free of corrosive substances (e.g.
halogenated hydrocarbons containing chlorines
or fluorines compounds).
- Do not install the appliance in a polluted atmos-
phere.
/B
:
23
23p
/C
):
13
33
recommendations
of