Circulating Pump Characteristics; Mixing Valve Characteristics; Characteristics Of The Expansion Vessel - geminox FCX 22 C Technical Instructions

Boiler water capacity up to 25l
Hide thumbs Also See for FCX 22 C:
Table of Contents

Advertisement

5 - CIRCULATING PUMP CHARACTERISTICS

The circulating pump is equipped with a 3-speed
motor with a 85 W (0.11 HP) maximum power input.
Fig. 3
35
30
25
20
15
10
5
0
0
2

6 - MIXING VALVE CHARACTERISTICS

Fig. 4
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
1
3
Setting button position

7 - CHARACTERISTICS OF THE EXPANSION VESSEL

FCX boilers are pre-equipped with an expansion
vessel for an installation water capacity of approxi-
mately 62 liters (16 gal) .(section 8.2 - page 26 -
chapter V - INSTALLATION)
The expansion vessel absorbs the increase in the
water volume in the installation produced by the in-
crease in temperature. The pre-inflation of the ves-
sel sends the internal membrane to the side of the
connection and the water dilation pushes on this
membrane. Optimum efficiency is obtained when
the inflation pressure is equal to the water pressure.
Note:
- The minimum water pressure necessary for the
correct working of the installation is defined by
the difference in levels between the boiler and the
3
2
1
6
4
8
10
Capacity in U.S. GPM
5
7
10
The heating pump's power consumption can be si-
gnificantly optimised by adapting its speed to the re-
quirements of the installation and by using the
control devices that are offered as options
15
20
25
30
35
40 45
10000
1000
100
10
1
100
highest point in the installation [ex : 8 m = 0,8 bar
(26ft=11.6 Psi)].
Fig. 5
Water inlet
Membrane
Inflating
Max vessel
volume
valve
- 11 -
TECHNICAL SPECIFICATIONS
HP range
1/25, 1/12, 1/6
Fluid temp
230°F Maximum
50°F Minimum
Flow Range
10-46 GPM
50
1000
Flow (l/h)
H
Dilated water
volume
Pressure rises
as the air is
compressed
10000