Tare Function; Change Of The Unit Of Measure - Scale House MB1 Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

5.3 TARE FUNCTION

Zero the scale by pressing the ZERO key if necessary. The zero symbol will be on.
Place a container on the platform, a value for its weight will be displayed. Press the TARE key to
tare the scale when the "stable" is light. The weight that was displayed is stored as the tare value
and that value is subtracted from the display, leaving zero on the display. The "NET" indicator will
be on. As product is added only the weight of the product will be shown.
The scale could be tared a second time if another type of product was to be added to the first one.
Again only the weight that is added after taring will be displayed.
When the container is removed a negative value will be shown.
To remove the tare, unload the scale and press again TARE.

5.4 CHANGE OF THE UNIT OF MEASURE

By pressing together TARE and ZERO keys the conversion between g and OZ units of measure
takes place; the relative symbol will turn on in the display (see section 4).