11
By-pass system to by-pass the dryer during service operations (available as an option,
consult Atlas Copco).
12
On water-cooled compressors:
Water flow and pressure to be adjusted depending upon local conditions.
For cooling water quality see section
A water shut-off valve and water drain valve should be installed by the customer in the
compressor water inlet pipe and outlet pipe. If water shut-off valves at the compressor water
inlet and outlet pipe are installed, a safety device with set pressure according to the
maximum cooling water inlet pressure (see section
has to be installed between the compressor water outlet pipe and shut-off valve. When
operating the unit, the operator must ensure that the cooling water system cannot be
blocked. The above-mentioned applies also to the energy recovery cooling water system.
Remove the plastic plugs (if provided) from the compressor water pipes and connect the
pipes to the cooling water circuit.
13
Cooling air grating, dryer

6.3 Electrical connections

Important remark
To preserve the protection degree of the electric cubicle and to protect its components from
dust from the environment, it is mandatory to use a proper cable gland when connecting the
supply cable to the compressor
100
Cooling water requirements.
Reference conditions and limitations)
Instruction book
9096 3313 00