Mounting
Lugs for
securing wires
>>
<<
Wire passage
J1
-
OTES:
-
Do not leave the battery connected when the control panel is not connected to the mains
(e.g. storage before installation). If this happens, the power used is 1mA.
-
The system parameter back-up by EEPROM requires no power supply.
-
Make sure that the panel battery is charged before use..
J1
L1
L2
P1
P2
J2
Transformer
+
+
-
SELV
J6
Pass all cables (PSTN, mains, wired extensions) into the panel
but do not connect them.
The power supply cable must be secured with cable ties (close
to J1) and these must be installed using the tool specified by the
cable tie manufacturer.
Fix the panel on the wall then connect all cables, following the
instructions below.
Note: Breakout tabs are supplied in the panel box for covering
unused wire passages.
Warning: This Class I system MUST be earthed
Connect the mains cable to the J1 terminal.
A built-in transformer ensures the supply to the control panel and
for charging the battery. The mains are protected by a fuse
integrated into the circuit board. This protects the electrical
system and cannot be removed.
A line protected with a fused switch or spur (depending on the
country) must be used for connecting the CMI800++ to the mains.
Use a flexible cable 3*0.75mm2 H03VV F2 or rigid cable
3*1mm2. Keep the earth about 2 cm longer than the other wires
and strip the wires for 7.5mm.
Connect the battery using the red and black wire with lugs.
Once the battery has been connected the system will not be
initialized until mains connection.