Walk Testing the Installation
Activate each sensor to check proper reception by the panel: the sensor serial number is displayed with the
radio level of the reception by the panel.
This test can also be used with other radio devices to check proper registering and radio reception on the
panel
1-REGISTER
2-DEVICES
3-PARAMETERS
4-DATE & TIME
5-SYSTEM DIAG.
6-TRANSM.STATUS
7-RADIO SCAN
8-ABORT
9-SAVE+QUIT
4.6 Closing the Panel
Only after programming/modification can the panel be closed. It can also be secured with a screw.
5.
Product Specifications
Dimensions
Temperature (CSEI - 11- 10 Standard)
Relative humidity (CSEI - 11- 10 Std)
Weight (with battery)
Power requirements
Battery
Typical consumption (Ut)
14
RADIO SCAN
------------------
S/N .........................
RF
....x/10......................
QUIT ( )
AGAIN (OK)
Height:
Width:
Max Depth:
Operating:
Storage:
Typical (Ut):
Type:
Fault threshold:
Max Depth:
Normal:
Calling :
Programming
83mm
235mm / 295mm depending on cover
50mm / 56mm
-10°C - +55°C
-40°C - +70°C
< 85%
1280 g (2822 lb)
Class I - 230V~ 50Hz, fused (100mA)
4V 3,5Ah max.
3,57 V
50mm / 56mm
with GPRS module
80 mA
100 mA
125 mA
270 mA