Air Controls; Operating Instructions - Parkray consort 9 CE V.II Installation And Operating Instructions Manual

Multifuel central-heating stove
Table of Contents

Advertisement

This appliance should not be operated with the doors open
Aerosol Sprays
Do not use an aerosol spray on or near the stove when it is alight.

Air Controls

This stove has been designed to burn cleaner and more efficiently than a conventional wood burning
stove. If used correctly this stove will burn far more efficiently than normal with the obvious notable
feature of CLEAN GLASS.
However, for this product to work properly it must be used correctly.
It is essential that the stove has an adequate air supply for combustion and ventilation.
The primary and secondary air inlets must be kept clear from obstruction and blockage.
Air Controls
Secondary Air Control (Open Right)
Primary Air
The thermostat at the rear of the stove controls the primary
air. The door sliders should be kept closed or the thermostat
will not be able to control the fire.
Secondary Air
Secondary air is controlled via the slider above the doors; it
is this "Airwash" that keeps a clean and uninterrupted view
of the fire.
Primary Air Control (Open Outwards)
Warning! This Appliance will be hot when in
operation and due care should be taken. The
riddling tool may be used to operate the door
handle. Thick gloves could be used to operate
the primary and secondary air controls.
Damper Assembly (Optional)
When the damper is set in the open position the chimney draws at full draught, increasing the volume
of airflow through the stove and flue. Shutting the damper restricts the flow, slowing the rate of
burning. Close all other air controls and allow the fire to die down before closing the damper.

Operating Instructions

This appliance is not suitable for use in a shared flue

Hide quick links: