Important Warning; Flue Collar; Assembly Instructions; Blanking Plate - Parkray consort 9 CE V.II Installation And Operating Instructions Manual

Multifuel central-heating stove
Table of Contents

Advertisement

PLEASE READ THESE INSTRUCTIONS CAREFULLY
It is important that your stove is correctly installed, as Parkray Limited cannot
accept responsibility for any fault arising through incorrect use or installation.
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit

Flue Collar

Place the Flue Gasket on the top or rear
outlet as required. Place the Flue Collar on
top of the Gasket. Secure to the four
locating tabs, inside the flue outlet, using
the M6 screws. Fit the 2 - M8 carriage
bolts, washers & nuts into the Damper
Holes, located on each side of the Flue
Collar.

Blanking Plate

Fit the Flue Gasket and Blanking Plate on the remaining free outlet and secure
it, using 4 - M6 screws.
Baffle

Assembly Instructions

Important Warning

fumes into the room.
Lift the Baffle and slide to the
right.
When the left side of the Baffle
clears the Baffle Support, lower
the Baffle into the Fire Box and
remove.
To refit the Baffle, simply
reverse the above procedure.