Viewing The Service Numbers; Oven Options; Turn On/Off "Adjust Time" Screen; Turn On/Off Edit Mode - TurboChef i3 Owner's Manual

Hide thumbs Also See for i3:
Table of Contents

Advertisement

viewing the Service Numbers

From the info mode (Figure 20), press the r4 soft
key to view technical support contact info.

Oven Options

From screen 2 of the info mode (Figure 21), press
the L2 soft key to access the "options" screen (Figure
24). When prompted, enter the password
and press the Enter key.
From the "options" screen, the following oven
options can be set:
- Turn on/off "Adjust Time" screen (page 12 for
more details)
- Turn on/off "Cook More" (Additional Cooking
options) screen (page 13 for more details)
- Turn on/off Edit Mode (page 17 for more details)
- Turn on/off "Load Menu" screen (page 16 for
more details)
- Access Network Setup (see below)
- Set oven Type: Ensure this option is set to "i3"
for i3 ovens and "i5" for i5 ovens.
- Demo Mode (TurboChef use only)

Network Setup

From the network setup screen, the following
information may be entered to configure the oven
for networking:
- IP Address
- Mask
- Gateway (GW)
- Domain Name Servers (DNS 1/DNS 2)
L1
OVEN OPTIONS
ADJ TIME
OFF
L2
COOK MORE
ON
L3
EDIT MODE
ON
L4
LOAD MENU
ON
L5
DEMO MODE
OFF
Figure 24: Options Screen
9 4 2 8
R1
NETWORK SETUP
R2
R3
R4
R5
OVEN TYPE I3
Each set of numbers may be edited in strings of three
digits:
1. To edit the first string, press the Down key and
then enter the first three digits.
2. Press the Down key again and enter the next three
digits.
3. repeat until all digits have been entered for each field.
4. Press "Save."
If DHCP is turned on (top-left corner of screen),
the oven will automatically be assigned an IP address
when connected to a local area network (if an IP
address is available). TurboChef recommends leaving
DHCP off to ensure the IP address on the oven does
not change.
using oven Connect requires each oven to be net-
worked. For help determining the correct network
setup information, contact your network administrator.

Setting the F2 Alarm

under normal operation, the F2 alarm will terminate
a cook cycle if the CC temperature falls below 84°F
(47°C) of the set point. Turning off the F2 alarm will
prevent a cook cycle from being terminated if the
fault is discovered. In either event, the fault will be
logged and should necessitate a service call.
To turn the F2 alarm on or off, press the r2 soft key
from the Info 2 screen (Figure 21, page 14).

Resetting the Oven

resetting the oven is one way to potentially clear an
error message, should one occur. From the "Cooling
Down" or "oven off" screen, press and hold the Info
key for five seconds.
BAC K
E NTE R
S TO P
15
1
2
3
A B C
D E F
4
5
6
G H I
J K L
M N O
7
8
9
P Q R S
T U V
W X Y Z
0
BACK
EN TER
STOP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I5

Table of Contents