For the installer

3

About the box

3.1

Overview: About the box

This chapter describes what you have to do after the box with the
outdoor unit is delivered on-site.
It contains information about:
▪ Unpacking and handling the outdoor unit
▪ Removing the accessories from the unit
▪ Removing the transportation stay
Keep the following in mind:
▪ At delivery, the unit must be checked for damage. Any damage
must be reported immediately to the carrier's claims agent.
▪ Bring the packed unit as close as possible to its final installation
position to prevent damage during transport.
▪ When handling the unit, take into account the following:
Fragile, handle the unit with care.
Keep the unit upright in order to avoid compressor
damage.
▪ Choose on beforehand the path along which the unit is to be
brought in.
▪ Lift the unit preferably with a crane and 2 belts of at least 8 m long
as shown in the figure below. Always use protectors to prevent
belt damage and pay attention to the position of the unit's centre
of gravity.
b
d
d
b
a
d
c
a
Packaging material
b
Belt sling
c
Opening
d
Protector
NOTICE
Use a belt sling of ≤20 mm wide that adequately bears the
weight of the unit.
▪ A forklift can only be used for transport as long as the unit remains
on its pallet as shown above.
RXYTQ8~16T7YF
VRV IV system air conditioner
4P388989-1B – 2016.02
technical
specifications,
c
▪ Format: Digital files on
http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
3.2

To unpack the outdoor unit

Relief the unit from its packing material:
▪ Take care not to damage the unit when removing the shrink foil
with a cutter.
▪ Remove the 4 bolts fixing the unit to its pallet.
WARNING
Tear apart and throw away plastic packaging bags so that
nobody, especially children, can play with them. Possible
risk: suffocation.
8 HP
3.3
To remove the accessories from
the outdoor unit
8 HP
10~16 HP
Make sure that all accessories are available in the unit.
a
b
c
REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
No.
1
2
3
4
5
6
7
8
MODELNAME
INSTALLATION
SITE
No.
11
12
13
14
15
16
17
18
MODELNAME
INSTALLATION
SITE
No.
21
22
23
24
25
26
27
28
MODELNAME
INSTALLATION
No.
SITE
31
32
33
34
35
36
37
38
MODELNAME
INSTALLATION
SITE
No.
41
42
43
44
45
46
47
48
MODELNAME
INSTALLATION
SITE
No.
51
52
53
54
55
56
57
58
MODELNAME
INSTALLATION
SITE
No.
61
62
63
64
MODELNAME
INSTALLATION
SITE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
SETTING
VALUE
REMARK
DATE
SETTING
VALUE
REMARK
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
4. MODEL NAME
5. MANUFACTURING NUMBER
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
a
General safety precautions
b
Installation manual and operation manual
c
Additional refrigerant charge label
3 About the box
10~16 HP
d
e
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
9
10
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
Total indoor unit
19
20
kg
capacity connection
Total indoor unit capacity
50%< CR < 105%
ratio (CR)
8HP
0
0
10-12HP 14-16HP 18-20HP
0
0.5
OUTDOOR
AMOUNT
ADDITIONAL CHARGING
PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O19.1 x 0.26
TOTAL LENGTH OF LIQUID
PIPE SIZE O15.9 x 0.18
when piping length <30m
50%< CR < 70%
105%< CR < 130%
0.5
0
0.5
0
0.5
0
0.5
1.0
29
30
UNIT
kg
(m) x 0.37
(m) x 0.26
(m) x 0.18
Total indoor unit capacity
when piping length >30m
85%< CR < 105%
70%< CR < 85%
0.3
0.7
0.5
1
0.5
1
1.0
1.5
105%< CR < 130%
1.2
1.5
1.5
2.0
TOTAL LENGTH OF LIQUID
PIPE SIZE O12.7 x 0.12
TOTAL LENGTH OF LIQUID
PIPE SIZE O9.5 x 0.059
PIPE SIZE O6.4 x 0.022
TOTAL LENGTH OF LIQUID
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
ONLY FOR RYYQ8~20 MODELS
RYYQ14-16
RYYQ18-20
0.9
1.1
1.3
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
49
50
DATE
AMOUNT
59
60
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
DATE
AMOUNT
DATE
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
3P328191-1