fire or other damage to the equipment. Be sure to use only accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional. Ask your dealer to move and reinstall the air conditioner.
Page 4
Consult the dealer if the air conditioner submerges owing to a Do not place the controller exposed to direct sunlight. natural disaster, such as a flood or typhoon. The LCD display may get discolored, failing to display the data. Do not operate the air conditioner in that case, or otherwise a Do not wipe the controller operation panel with benzine, thinner, malfunction, electric shock, or fire may result.
13 ICON " " (DEFROST/HOT START) HAT TO DO BEFORE OPERATION This icon indicates that the defrost/hotstart mode is active. Refer This operation manual is for the following systems with standard to the chapter "Explanation of heating operation" on page control.
Adjustment PERATION RANGE For programming temperature, fan speed and air flow direction, follow the procedure as explained below (only for remote controller of Operation range type BRC1A51: FXC, FXF, FXH, FXK and FXA). Use the system in the following temperature and humidity ranges for Press the temperature setting button and set the safe and effective operation.
6.2. Program dry operation 6.3. Adjusting the air flow direction (only for Double- flow, Multi-flow, Corner, Ceiling-suspended and Wall-mounted) The function of this program is to decrease the humidity in your Press the air flow direction button to select the air flow room with minimal temperature decrease (minimal room direction.
6.6. Precautions for group control system or two Press the timer on/off button. remote controller control system The timer setting procedure ends. The display " " or " " changes from flashing to constantly lit. This system provides two other control systems beside individual control (one remote controller controls one indoor unit) system.
Symptom 3: Fan operation is possible, but cooling and heating do not AINTENANCE work. Immediately after the power is turned on. The micro computer is getting ready to operate. Wait 10 Pay attention to the fan. minutes. It is dangerous to inspect the unit while the fan is running. Be sure to turn off the main switch and to remove the fuses Symptom 4: The fan strength does not correspond to the setting.
10. T Symptom 8.2: Indoor unit, outdoor unit ROUBLESHOOTING A continuous low hissing sound is heard when the system is in cooling or defrost operation. If one of the following malfunctions occur, take the measures shown This is the sound of refrigerant gas flowing through both indoor below and contact your dealer.
11. A Table 1 assumes the following conditions of use: FTER SALES SERVICE AND WARRANTY Normal use without frequent starting and stopping of the unit. Warranty period Depending on the model, we recommend not starting and stopping the machine more than 6 times/hour. This product includes a warranty card that was filled out by the dealer at the time of installation.
Need help?
Do you have a question about the RXYQ8P7Y1K and is the answer not in the manual?
Questions and answers
how meny kw/h consumption for this model unit RXYQ12P7YLK
The Daikin model RXYQ12P7YLK has a current rating of 24.1 A at 380 V and 60 Hz. To calculate the power consumption in kilowatts (kW):
Power (kW) = √3 × Voltage (V) × Current (A) / 1000
= √3 × 380 × 24.1 / 1000
≈ 1.732 × 380 × 24.1 / 1000
≈ 15.87 kW
If the unit runs for 1 hour, it consumes approximately 15.87 kWh.