Specification
(f)
▪ Sound power
(g)
▪ Sound pressure
Refrigerant
▪ Type
▪ Charge
Refrigerant oil
Safety devices
(a)
Nominal cooling capacities are based on T1 (indoor temperature: 26.7°C DB, 19.4°C WB, outdoor temperature: 35°C DB, AHRI 1230:2010,
power input indoor units (duct type) included), T2 (indoor temperature: 26.6°C DB, 19.4°C WB, outdoor temperature: 48°C DB, AHRI 1230:2010,
power input indoor units (duct type) included), T3 (indoor temperature: 29.0°C DB, 19.0°C WB, outdoor temperature: 46°C DB, ISO15042:2011,
power input indoor units (duct type) included), Eurovent (indoor temperature 27.0°C DB, 19.0°C WB, outdoor temperature: 35°C DB,
Eurovent 2015, power input indoor units (duct type) excluded).
(b)
Nominal heating capacities are based on indoor temperature 20°C DB, outdoor temperature 7°C DB and 6°C WB, Eurovent 2015, equivalent
refrigerant piping: 5 m, level difference: 0 m.
(c)
Actual number of units depends on the indoor unit type (VRV DX,...) and the connection ratio restriction for the system (50%≤CR≤130%).
(d)
Nominal at 230 V.
(e)
Sound values are measured in a semi-anechoic room.
(f)
Sound power level is an absolute value that a sound generates.
(g)
Sound pressure level is a relative value depending on the distance and acoustic environment. For more details, refer to sound level drawings in
the technical data book.
Electrical specifications
Specification
Power supply
▪ Name
▪ Phase
▪ Frequency
▪ Voltage at 50 Hz
▪ Voltage at 60 Hz
Current
▪ Nominal running current (RLA)
(b)
▪ Starting current (MSC)
▪ Minimum circuit amps (MCA)
(d)
▪ Maximum fuse amps (MFA)
▪ Total overcurrent amps (TOCA)
(f)
▪ Full load amps (FLA)
Voltage range at 50 Hz
Voltage range at 60 Hz
Wiring connections
▪ For power supply
▪ For connection to indoor unit
Power supply intake
(a)
RLA is based on indoor unit temperature 27°C DB and 19°C WB, outdoor temperature 35°C DB.
(b)
MSC=the maximum current during startup of the compressor. VRV IV uses only inverter compressors. MCA must be used to select the correct
field wiring size. The MCA can be regarded as the maximum running current.
(c)
MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
(d)
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
(e)
TOCA means the total value of each OC set.
(f)
FLA=nominal running current fan. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not
below or above listed range limits. Maximum allowable voltage range variation between phases is 2%.
RXYTQ8~16T7YF
VRV IV system air conditioner
4P388989-1B – 2016.02
8 HP
78 dBA
58 dBA
6.7 kg
▪ High pressure switch
▪ Fan driver overload protector
▪ Inverter overload protector
▪ PCB fuse
8 HP
(a)
8 A
(c)
16.1 A
20 A
(e)
17.3 A
1.2 A
10 HP
12 HP
81 dBA
61 dBA
R410A
10.3 kg
10.4 kg
Synthetic (ether) oil
10 HP
12 HP
Y1
3N~
50 Hz/60 Hz
380-415 V
400 V
9.3 A
12.7 A
≤MCA
22 A
24.0 A
25 A
32 A
28 A
1.8 A
380-415 V ±10% V
400 V ±10% V
5G
2 (F1/F2)
both indoor and outdoor unit
12 Technical data
14 HP
16 HP
86 dBA
64 dBA
11.7 kg
11.8 kg
14 HP
16 HP
15.8 A
19.3 A
27.0 A
31.0 A
40 A
35.4 A
2.6 A
Installer and user reference guide
59