Monitoring the DSU

Self-Test Results

4-4
Table 4-2. Health and Status Messages (2 of 2)
Message
What Message Indicates
Device Fail
An internal error has been
yyyyyyyy
detected by the operating
software. yyyyyyyy indicates
the 8-digit hexadecimal failure
code.
DSU Operational
DSU is functioning properly
and there are no status
messages to display.
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-3. Self-Test Results Messages
Message
What Message Indicates
Device Fail
One or more of the DSU's integrated
circuit chips has failed device-level
testing.
Memory Fail
DSU failed memory verification.
Passed
The DSU has been plugged in or
reset and has passed the diagnostic
test. There are no other status
messages.
March 1997
What To Do
1. Provide the 8-digit failure code
shown ( yyyyyyyy ) to your service
representative.
2. Reset the DSU to clear the
condition and message.
No action needed.
What To Do
1. Reset the DSU and try again.
2. Call your service
representative for assistance if
representative for assistance if
the message reappears.
No action needed.