Monitoring the DSU

Viewing Network Interface Status

4-6
The network interface status fields are read-only:
Line Rate (Kbps). If the DSU is connected to an operating line and the Line
Rate (Kbps) shows Autobaud and does not change to a line rate within about
15 seconds, Line Rate (Kbps) may have to be reconfigured manually. Refer
to
Network Interface
Loop Loss (dB). The loop loss is the loss of signal strength of the receive line
signal from the local loop.
To view the Network Interface Status, follow this menu selection sequence:
Main Menu
Status
Table 4-5 describes the contents of the Network Interface Status screen.
Table 4-5. Network Interface Status Screen Contents
Field
Status
Line Rate (Kbps)
56 Kbps
64 CC
64 LADS
64 LADS
Autobaud
No Signal
Loop Loss (dB)
0 to – 65 dB
Inoperative
March 1997
Options, Table A-2.
Network Interface Status
What the Status Indicates
Line rate on the network interface.
Autobaud indicates the DSU is
trying to determine the network line
trying to determine the network line
rate. This should be a temporary
condition.
No signal can be detected over the
network interface.
Amount of loop loss – loss of signal
strength of the receive line signal
from the local loop, measured in
decibels.
The line may be disconnected.