Electrical, Fuel Hose And Control Cables; Front Cover Assembly - Mercury optimax 115 Installation Manual

Hide thumbs Also See for optimax 115:
Table of Contents

Advertisement

75/90/115 OPTIMAX
Electrical, Fuel Hose, and Control Cables
IMPORTANT: Warning Horn Requirement – The remote control or key switch assem-
bly must be wired with a warning horn. This warning horn is used with the engine
warning system.

Front Cover Assembly

REMOVAL
Pull up the cowl seal and remove the cover from the bottom cowl.
a
b
INSTALLATION
IMPORTANT: Sufficient slack must exist in engine wiring harness, battery cables,
fuel hose, and routed between clamp and engine attachment point, to relieve stress
and prevent hoses from being kinked or pinched.
1. Route the fuel hose, wiring and cables through the front cover opening.
2. Route flush hose (if equipped) through front cover opening.
3. Place the neoprene wrap around the wiring, hoses, and control cables as shown. Rein-
stall the cover and cowl seal.
d
Page 8 of 18
a -
Screws (2)
b -
Cover
b
c
a
a -
Neoprene Wrap
b -
Screws (2)
c -
Cover
d -
Flush Hose (if equipped)
a
b

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optimax 75Optimax 90