C. Approved Pipe
Approved Pipe - Rigid
This appliance is approved for use with Hearth & Home
Technologies DVP or SLP venting systems. Refer to Sec-
tion 12.A for vent component information and dimensions.
DO NOT mix pipe, fi ttings or joining methods from differ-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appli-
ance requires a separate vent. DO NOT vent to a pipe
serving a separate solid fuel burning appliance.
Approved Pipe - Flex
This appliance is approved for use with Hearth & Home
Technologies SLP-FLEX (6-5/8 in.) and SLP-FLEX7 (7
inch) venting systems.
DO NOT mix pipe, fi ttings or joining methods from differ-
ent manufacturers. SLP-FLEX and SLP-FLEX7
venting cannot be interchanged.
SLP-FLEX (6-5/8 Inch): venting may be used in any
venting confi guration shown in the venting tables provid-
ed that the horizontal vent length is reduce by 25%.
SLP-FLEX7 (7 Inch): venting may only be used with one
elbow, horizontally terminating appliacations. SLP-FLEX7
Requires adapter collars to tranisition from the 6-5/8"
appliance starting collar and the 6-5/8" termination cap.
Refer to installation instructions included with the SLP-
FLEX7 collar adapter (SLP-FLEX7-AM).
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appli-
ance requires a separate vent. DO NOT vent to a pipe
serving a separate solid fuel burning appliance.