Fujitsu AUXG18LRLB Technical Manual page 12

Cassette type
Hide thumbs Also See for AUXG18LRLB:
Table of Contents

Advertisement

 Various energy saving control
• Auto-off timer
– The indoor unit automatically turns off after the set time has passed.
– The time interval for which auto-off works can be set.
Example: At interval time hour (17:00 to 24:00) to prevent forgetting to turn off.
• 2 schedules weekly timer
– 2 schedules such as for the summer and winter can be set.
– 8 setting changeable per day of week (Setting items: on/off, temperature, mode, and time)
Setting example:
Schedule 1 (Summer schedule)
Setting temp.
On
26 °C
24 °C
8:40
• Set temperature auto return
– The setting temperature automatically returns to the previous setting temperature.
– The time range in which the set temperature can be changed is 10 to 120 minutes.
Setting temp.
Set temperature change
24 °C
22 °C
• Set temperature upper and lower limit setting
The set temperature range can be set for each operation mode (COOL, HEAT, and AUTO).
30 °C
25 °C
18 °C
Original temp.
setting range
Set interval time hour (17:00 to 24:00)
On
Set off time
(30 to 240 minutes)
17 :
0
0
Off
Off
Time
11:40
17:30
20:40
Cooling operation
Auto return
Settable time range
10 to 120 minutes
Time
11:40
13:40
During cooling
Lower limit
setting
Auto-off
Off
2
4
: 00
Schedule 2 (Winter schedule)
Setting temp.
On
25 °C
23 °C
8:40 10:00
15:30
Heating operation
Set temperature change
Setting temp.
25 °C
23 °C
Settable time range
10 to 120 minutes
11:40
During heating
30 °C
25 °C
16 °C
Original temp.
setting range
- 6 -
Off
Off
Time
17:30
20:40
Auto return
Time
13:40
Upper limit
setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents