5-5. Model: AOYG45LBTA
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
HEATING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
5
7.5
30
-
-
20
-
-
10
-
-
7.5
-
0.988
5
0.992
0.992
0
1.000
1.000
-5
1.000
1.000
-7.5
-
1.000
-10
-
-
-20
-
-
-30
-
-
5
7.5
30
-
-
20
-
-
10
-
-
7.5
-
1.000
5
1.000
1.000
0
1.000
1.000
-5
0.998
0.995
-7.5
-
0.993
-10
-
-
-20
-
-
-30
-
-
- 108 -
Pipe length (m)
10
20
30
-
-
0.879
-
0.926
0.893
0.975
0.942
0.908
0.979
0.946
0.912
0.983
0.949
0.916
0.991
0.957
0.923
0.991
0.957
0.923
0.991
0.957
0.923
0.991
0.957
0.923
-
0.957
0.923
-
-
0.923
Pipe length (m)
10
20
30
-
-
0.978
-
0.988
0.978
0.998
0.988
0.978
0.998
0.988
0.978
0.998
0.988
0.978
0.998
0.988
0.978
0.993
0.983
0.973
0.991
0.981
0.971
0.988
0.978
0.968
-
0.968
0.958
-
-
0.949
40
50
0.846
0.814
0.861
0.828
0.875
0.841
0.878
0.845
0.882
0.848
0.889
0.855
0.889
0.855
0.889
0.855
0.889
0.855
0.889
0.855
0.889
0.855
40
50
0.968
0.958
0.968
0.958
0.968
0.958
0.968
0.958
0.968
0.958
0.968
0.958
0.963
0.953
0.961
0.951
0.958
0.948
0.949
0.939
0.939
0.929