10-4.Details Of Function - Fujitsu AUXG18LRLB Technical Manual

Cassette type
Hide thumbs Also See for AUXG18LRLB:
Table of Contents

Advertisement

10-4. Details of function
 Control input function
 When function setting is "Operation/Stop" mode 1
• In the case of "Edge" input
Function
External input and
setting /
46-00
Indoor unit
• In the case of "Pulse" input
Function
External input and
setting /
46-00
Input 1
Input 2
Operation
Indoor unit
Remote controller
NOTES:
• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.
Rotary SW of
output PCB
-
Input of indoor unit
External input and
60-00 / 1
On
Input
Off
Operation
Stop
Remote controller
Rotary SW of
output PCB
External input and
60-00 / 1
On
Off
On
Off
Stop
External input
Terminal
Input 1
output PCB
On
External input
Input 1
output PCB
Input 2
On
- 59 -
Input signal
Command
Off → On
Operation
On → Off
Stop
Off → On
Operation
On → Off
Stop
Input signal
Command
Pulse
Operation
Pulse
Stop