Stop The Engine; Using The Unit As A Welding Generator - Gen Set MPM 6/230 S-L Use And Maintenance Manual

Motor welding set / generating set
Table of Contents

Advertisement

pic.3
4
3
2

07.4 STOP THE ENGINE

• Disconnect the loads.
• Turning the key switch (2) in "OFF" position.
07.5 USING THE UNIT AS A WELDING
GENERATOR (picture 4)
• Plug the welding cables in the relating receptacles (10)
(positive), (9) (negative).
• The welding current control is achieved by acting on the
Welding Current Control (5).
• The activation of the arc force is achieved by setting the
switch (7) in "ON" position.
• If the welding current remote control is used (provided
only upon request) set the Remote Control switch (6) to
position "ON" and connect the remote control device to
receptacle (8).
SHIELDED METAL ARC WELDING
(picture 4)
(SMAW)
• Connect the welding cables to the respective receptacles
(9) negative and (10) positive.
• Position the Remote Control switch (6) to "OFF" position.
• Adjust the welding current using the Welding Current
Control (5).
• If the welding current remote control is used (provided
only upon request), this must be connected to the 3 poles
receptacle (8), the Remote Control switch (6) must be in
"ON" position, and the welding current is adjusted by acting
on the remote control.
07. USING THE MACHINE
(picture 3)
• The activation of the arc force is achieved by setting the
switch (7) in "ON" position.
• For basic and cellulosic electrodes the electrode holder
must be connected to receptacle (10) (positive) and the
work clamp to receptacle (9) (negative).
• For rutile and acid electrodes, it is advised to connect the
electrode holder to receptacle (9) (negative) and the work
clamp to receptacle (10) (positive).
GAS TUNGSTEN ARC WELDING (GTAW)
LIFT START ONLY
• Connect the electrode holder to receptacle (9) (negative)
and the work clamp to receptacle (10) (positive).
• Position the Remote Control switch (6) to "OFF" position.
• Adjust the welding current using the Welding Current
Control (5).
• If the welding current remote control is used (provided
only upon request), this must be connected to the 3 poles
receptacle (8), the Remote Control switch (6) must be in
"ON" position, and the welding current is adjusted by acting
on the remote control.
• The activation of the arc force is achieved by setting the
switch (7) in "ON" position.
pic.4
5
6
7
8
9
GB
(picture 4)
10
MPM 6/230 S-L
31
MI-M-00006200