Page 1
MPM 6/230 S-L MANUAL NUMBER MI-M-00006200 REVISION LEVEL 00 25-01-2016 MOTOR WELDING SET / GENERATING SET FOR STATIONARY USE USE AND MAINTENANCE MANUAL GEN SET S.p.a. Via Stazione,5 - 27030 Villanova D’Ardenghi (Pavia) Italy Tel. (+39) 0382-5091 - Fax (+39) 0382-509-244...
Page 2
It is recommended to read this manual thoroughly because incorrect operation may result in the warranty being void. Therefore it is also recommended to use only original Gen Set S.p.a. spare parts. Reproduction of this manual is not permitted, unless written approval is obtained from...
01. REFERENCE GUIDE 01.1- This publication........................page 5 01.2- Purpose..........................page 5 01.3- Reference to regulations......................page 5 01.4- Using this manual........................page 6 01.5- Terminology..........................page 6 01.6- Abbreviations........................page 6 MPM 6/230 S-L MI-M-00006200...
Page 5
CE Marking relating to the EC Declaration of Conformity. The marking of the sound power level guaranteed consists of a number in dB, mark and the specific symbol: MPM 6/230 S-L MI-M-00006200...
Explanation of some of the terms relating to the power generator and used in this publication. sound pressure : the part of the unit where the control panel is located. FRONT dB(A) decibel MPM 6/230 S-L MI-M-00006200...
02.1- Precautions to be observed....................page 8 02.2- Risks for the operator when using this unit................page 9 02.3- Protective clothing recommended for operators..............page 9 02.4- Meaning of safety signs......................page 10 02.5- Location of safety signs provided on the unit................page 13 MPM 6/230 S-L MI-M-00006200...
• Use fume extractors to ensure the correct air turnover when operating indoors. • Do not operate near flammable materials. • Fill fuel tank when engine is stopped. Do not smoke when fuelling. • Do not overfill the tank and clean up any spilled fuel. MPM 6/230 S-L MI-M-00006200...
• Install and maintain equipment according to regulations. • Protective ear plugs and/or earmuffs • Switch off the generator and disconnect the battery before performing any service or repairs. N.B.: material not supplied. • Read and follow all the instructions in this Manual. MPM 6/230 S-L MI-M-00006200...
Danger of electric discharges: read the manual. MPM 6/230 S-L MI-M-00006200...
Page 11
Prohibition of cleaning, lubricating, repairing or adjusting moving parts. Prohibition of extinguishing fires with water; use fire extinguishers containing proper extinguishing agents. Prohibition of using flames or smoking. MPM 6/230 S-L MI-M-00006200...
Page 12
This card warns that the battery that the has no acid. Before starting the generator, prepare the battery according to the instructions of Chapter "06". Marks the position of the points for lifting the unit using a fork lift. MPM 6/230 S-L MI-M-00006200...
03. ENVIRONMENTAL DIRECTIONS 03.1- Waste material and lubricating oil..................page 15 03.2- Disposal of the unit......................page 15 MPM 6/230 S-L MI-M-00006200...
Page 15
Do not dispose of any type of lubricating oil, mineral or synthetic, onto land,drains or sewers. Dispose of batteries as instructed by local legislation. MPM 6/230 S-L MI-M-00006200...
04. THE MACHINE 04.1- Machine components......................page 17 04.2- Control panel description.....................page 19 MPM 6/230 S-L MI-M-00006200...
Page 17
04. THE MACHINE 04.1 MACHINE COMPONENTS Tappo rifornimento carburante Air vent screen Control panel Engine access Data plate Intake Battery access Intake Lifting eye Oil filler cap access Intake Exhaust vent Intake Intake MPM 6/230 S-L MI-M-00006200...
Page 18
04. THE MACHINE Air filter Fuel filter Engine oil level dipstick Engine oil filler cap Oil drain cap Oil drain plate Engine bay view MPM 6/230 S-L MI-M-00006200...
Page 19
13. 415 V 16 A three-phase current socket 14. 240 V 16 A single-phase current socket 15. 110 V 32 A single-phase current socket 16. Emergency stop button 17. Welding socket: Positive 18. Welding socket: Negative MPM 6/230 S-L MI-M-00006200...
Page 21
TIG welding: V = (I x 0,04) + 10 For current values higher than 600 A: V = 34 V Where V is the voltage at the welding receptacles and I is the welding current selected. MPM 6/230 S-L MI-M-00006200...
Page 22
Consumption per hour (at 75% of continuous service) 1,5 l/h 05.5 GENERAL SPECIFICATIONS Noise power emission level Battery 12 V - 44 Ah Fuel tank capacity 10,5 l Operating range at 75% of continuous service power Dry weight 185 Kg MPM 6/230 S-L MI-M-00006200...
Page 23
8. OCV - Open circuitry voltage (at no load) 21. Altitude reference 9. Three/Single-phase voltage generator 22. Ambient temperature 10. Engine speed 23. EC mark 11. Insulation class 24. Manufacturer’s address 12. Noise level 13. Unit’s degree of protection MPM 6/230 S-L MI-M-00006200...
Page 24
05. TECHNICAL DATA 05.7 OVERALL DIMENSIONS dimensions in mm 1083 Trolley-mounted unit ( dimensions in mm MPM 6/230 S-L MI-M-00006200...
To refuel the machine proceed as here under indicated: • Remove the fuel cap (4). • Proceed to fill up the fuel tank. • Put the fuel cap back on. • In case, clean up any spilled fuel immediately before starting the machine. pic.2 MPM 6/230 S-L MI-M-00006200...
Operate in open, well-ventilated areas; if operated indoors, vent the engine exhaust outside the building and make sure that the room has good air turnover. Keep the engine exhaust outlet away from building exterior and interior walls and air intakes. MPM 6/230 S-L MI-M-00006200...
70% of the maximum power output rated in the technical specifications. After first 50 hours of operation change the engine oil. MPM 6/230 S-L MI-M-00006200...
31 07.5- Using the unit as a welding generator..................page 31 07.6- Using the unit as a generating set..................page 32 07.7- Adjustments and settings.....................page 32 07.8- Putting the machine temporarily out of service and restarting operation.........page 32 MPM 6/230 S-L MI-M-00006200...
Do always connect the power generator to any load, to allow the regular warm-up. The unit is running earth. Check that the cables are in perfect at low rpm. condition. • Now it is possible to insert the load. MPM 6/230 S-L MI-M-00006200...
• If the welding current remote control is used (provided only upon request), this must be connected to the 3 poles receptacle (8), the Remote Control switch (6) must be in “ON” position, and the welding current is adjusted by acting on the remote control. MPM 6/230 S-L MI-M-00006200...
When putting the generator back to service, all fluids should be replaced, the battery should be charged, engine belts, if any, all couplings and fuel pipes and seals should be checked. In case of longer out of service periods, contact Gen Set Service Department. pic. 5...
08. MOVING THE MACHINE 08.1- Packing, transporting and storing the unit................page 34 08.2- Lifting and moving the unit....................page 34 MPM 6/230 S-L MI-M-00006200...
Page 34
Lay the generator on the ground gently. When lifting and moving the generator, do not stay or walk within it’s proximity. Never leave the generator slung overhead When moving and transporting the generator, do not tilt it excessively. MPM 6/230 S-L MI-M-00006200...
Page 37
• Pull the dipstick out and clean it with cloth or paper towels. • Fully push the dipstick back into its seating. • Pull the dipstick out again and check that the lubricating oil level is between the minimum and maximum marks. MPM 6/230 S-L MI-M-00006200...
Page 38
). Introduce new oil through the cap (6). Wait at least five minutes, then check the oil level again. It is important that the unit is sitting on level ground. pic.2 Engine oil grade table MPM 6/230 S-L MI-M-00006200...
Page 39
Remount the air filter paying attention that the o-ring is properly inserted, then tighten the finned nut 1. Make sure that the filter is mounted in the correct way otherwise dust and other impurities could ilfiltrate into the intake ducts. MPM 6/230 S-L MI-M-00006200...
Page 40
Apply only to authorised factory centres for any unplanned and laws relating to disposal of waste service operations related to electrical components. materials. Apply to service centres authorised by the manufacturer of the engine for any problems related to the engine. pic.3 MPM 6/230 S-L MI-M-00006200...
Page 46
11. SPARE PARTS MPM 6/230 S-L MI-M-00006200...
Page 47
11. SPARE PARTS List of spare part codes t l i t l i MPM 6/230 S-L MI-M-00006200...
Page 48
11. SPARE PARTS MPM 6/230 S-L MI-M-00006200...
Page 49
11. SPARE PARTS List of spare part codes MPM 6/230 S-L MI-M-00006200...
Page 50
11. SPARE PARTS MPM 6/230 S-L MI-M-00006200...
Page 51
GENERATOR SET IS DESIGNED TO OPERATE IN AMBIENT TEMPERATURES UP TO 40°C AND 1000 MT ALTITUDE − FOR HIGHER VALUES OF TEMPERATERES AND ALTITUDES PLEASE CONSULT FACTORY TO CHECK AVAILABLE POWER ISO 8528 146434 i t i t t i MPM 6/230 S-L MI-M-00006200...
13. ATTACHMENTS 13.1- List of documents........................page 55 13.2- Statement of warranty......................page 55 MPM 6/230 S-L MI-M-00006200...
Page 55
• Warranty card. 13.2 STATEMENT OF WARRANTY GEN SET S.p.A. warrants its products, on condition that they are not altered, for a period of 24 months beginning on the date of sale to the first user. Within this time period, in the countries where a service organisation is established, GEN SET S.p.A. undertakes to replace or repair the defective parts because of material defects, workmanship and/or assembly by means of its own AUTHORISED WOKSHOPS.