BATTERY
The unit is delivered with a fully charged
battery (disconnected)
The battery is factory filled with acid at density of 1.28 g/
ml and is ready for operation.
If the starting power is not enough, it is advisable to further
charge the battery as follows. For this operation it is
advisable to wear protective gloves and acid resistant
overalls.
• Remove the panel (1).
• Disconnect battery cables starting from the negative
terminal and remove the battery from the unit.
• Remove battery caps.
• Make sure that the room where the recharging will take
place is properly ventilated.
• Use only a DC battery charger with a proper voltage to
the system.
• Connect to the battery charger the positive terminal first
and then the negative terminal.
• Operate the battery charger. It is advised that the charging
current be about 1/10 of the value of battery capacity (e.g.
for a 44 Ah battery it is advised that the charging current
be about 4,4 A).
• The battery is deemed fully charged if the charging voltage
has no increased within the two hours.
In case of accidental contact with the battery
acid it is advised to:
• Wash immediately with clean water any
splash of acid into the eyes. Seek medical
advice as soon as possible.
• Wash immediately with clean water any
splash of acid onto the skin or clothing.
• In case of ingestion of acid: seek medical
advice immediately.

06.2 MAXIMUM OPERATING ANGLES

Do not exceed the operating angles shown in
the picture 4 while running the power
generator unit, or engine damage will occur.

06.3 LOCATION

A proper installation site should be selected for the power
generator if the unit is to provide dependable service.
Operate in open, well-ventilated areas; if
operated indoors, vent the engine exhaust
outside the building and make sure that the
room has good air turnover. Keep the engine
exhaust outlet away from building exterior
and interior walls and air intakes.