Paramount Fitness PCC2000 Owner's Manual

Paramount Fitness PCC2000 Owner's Manual

Cleaning system
Hide thumbs Also See for PCC2000:

Advertisement

Cleaning System Manual
OWNER'S MANUAL
For PCC2000, PV3, PVR, Cyclean, Pool Valet,
New Gen Pool Valet, Vantage,
Vanquish, VectorJet and EcoPool
004-027-8742-00 REV032516
US and Foreign patents and patents pending see
www.1paramount.com/about/patents/
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com

Advertisement

Table of Contents
loading

Summary of Contents for Paramount Fitness PCC2000

  • Page 1 Cleaning System Manual OWNER’S MANUAL For PCC2000, PV3, PVR, Cyclean, Pool Valet, New Gen Pool Valet, Vantage, Vanquish, VectorJet and EcoPool 004-027-8742-00 REV032516 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate Place • Suite 100 • Chandler, AZ 85225 Toll Free: 1.800.621.5886 •...
  • Page 2 Signal Words and Symbols Used In This Manual This Owner’s Manual and Installation Guide contains specific precautions and symbols to identify safety-related information. You will find DANGER, CAUTION, WARNING and NOTICE symbols which require special attention. Please read them carefully and follow these precautions as indicated! They will explain how to avoid hazards that may endanger you or persons using or maintaining your pool or spa.
  • Page 3 SUCTION ENTRAPMENT HAZARD: DEATH or SERIOUS INJURY will result if a drain cover or grate is not installed and used correctly. DANGER • Pool and spa pumps produce high levels of suction and move high volumes of water, which can cause death or serious injury if a person comes in close proximity to pool or spa drains.
  • Page 4: Table Of Contents

    Congratulations on your new pool and thank you for choosing one of Paramount’s cleaning or circulation systems. This manual will address all of Paramount’s systems, the PCC2000, PV3, PVR, Cyclean, Pool Valet, New Gen Pool Valet, Vantage, Vanquish, Step Clean and Eco Pool. Your system may also include a Paramount debris canister and one or more of Paramount’s Drains (MDX-R3, MDX2, Buzztop Channel Drain and/or SDX).
  • Page 5: What Is A Water Valve

    WHAT IS A WATER VALVE? The Paramount water valve is fully automatic and operates whenever the pump it’s connected to is running. Your Paramount water valve may be connected to your filter pump or a stand-alone “booster” pump. The water valve automatically distributes water to different areas of your pool, which can include the floor, steps, benches, spa and water features.
  • Page 6: Unique Water Valve Features

    UNIQUE WATER VALVE FEATURES The run/pause switch on the top of the valve allows you to pause the system to isolate a circuit in an out of the way area of the pool. The one-piece replacement module design allows for easy installation. The gauge on your water valve is important and tells you how the system is operating.
  • Page 7: Water Valve Part Numbers

    WATER VALVE PART NUMBERS 005-302-3590-00 Pressure Gauge 005-302-3502-00 Pause Assembly Includes: Screw Knob, O-Ring & Pawl 005-302-4300-03 Top Dome Complete Includes: Top, Gauge & Pause Assembly Modules: 004-302-4400-00 2 Port 4 Gear 004-302-4402-00 2 Port 5 Gear 004-302-4404-00 3 Port 004-302-4406-00 4 Port 004-302-4408-00...
  • Page 8: Water Valve Instructions

    WATER VALVE INSTRUCTIONS Turn off all equipment including pumps. Do not stand over valve while the pump is on. Warning: A hazardous WARNING situation which, if not avoided, could result in death or serious injury. How to open the water valve 1.
  • Page 9 Turn off all equipment including pumps. Do not approach the water valve while the lid is removed and WARNING the pump is on. Failure to do so can result in injury or death. . A hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 10: Module Alignment

    MODULE ALIGNMENT Module Installation & Alignment Guide (2-port, 3-port, 4-port) 2-port module alignment On the 2-port module the ports on top of the module that are attached together by connectors must be centered over the open ports in the valve base. 2 PORT / 4 GEAR // MODULE, BASE 2 PORT / 5 GEAR // MODULE, BASE Used for basin &...
  • Page 11 4-port module alignment 4 PORT // MODULE, BASE On the 4-port module the ports on top of the module that are attached Found on 9 port systems - feeds 6 port valve together by a connector must be aligned over the half of the base that has only one port.
  • Page 12: Run/Pause Control Switch

    RUN/PAUSE CONTROL SWITCH The run/pause control switch is used to stop the cleaning system circuits Figure 6 from cycling. When switched to the pause position, it will stop on the circuit that is up at that time. The run/pause control switch should only be used when you desire the nozzles not in the up position to remain down or while servicing the system.
  • Page 13: Nozzles (Cleaning Heads)

    18 cycles for a nozzle to rotate 360 degrees. There are two exceptions to this. The PCC2000 and Vantage systems can have one to three nozzles (called Fixed Nozzles) that do not rotate and remain active while pool filter pump is on.
  • Page 14 Method 2: Small Nozzles Figure 8 Some PCC2000 systems used the large floor nozzle in the steps. See Method 1 for removal and installations instructions. PV3, Cyclean and PCC2000 step nozzles see Figure 8. Using the removal tool common to these nozzles, attach the tool to the end of your pool pole placing it over the nozzle and making sure the tool tabs insert into the nozzle slots.
  • Page 15: Optional Paramount Debris Canister

    OPTIONAL PARAMOUNT DEBRIS CANISTER Your pool may be equipped with the Paramount optional deck side debris canister (DDC), which would be located in the deck next to your pool or the equipment side debris canister (EDC) on the equipment pad. The debris canister is where the debris from your pool is gathered after it passes through the drain.
  • Page 16 Cleaning Systems Powered by a Booster Pump Because booster pump systems are designed to pull from the skimmer(s) and not use a filter, they are not affected by the typical reductions in performance that affect filter pump systems. Booster pumps need to produce a minimum of 65 gpm (246 lpm) at 60 ft. (179kpa of head). It is important to keep the skimmer and pump basket(s) empty, so your pool equipment will power your in-floor system.
  • Page 17: Operating Instructions

    On PCC2000 and Vantage systems that may have fixed nozzles they may need to be adjusted to keep their flow of water aimed in the direction of the debris drain.
  • Page 18: Troubleshooting

    If there are any pistons in the open position, push system is off. NOTE: PCC2000 AND VANTAGE BOOSTER them shut being sure not to rotate them. Place the PUMP SYSTEMS MAY HAVE FIXED NOZZLES...
  • Page 19 An area around one nozzle Cleaning nozzle is partially or completely blocked. Refer to the Nozzle/Installation and Removal section. that is going up and down is Remove the nozzle. With the nozzle removed turn on the not being cleaned. system pump to blow out the circuit. Check the nozzle for debris stuck inside.
  • Page 20: In-Floor Warranty Registration

    IN-FLOOR WARRANTY REGISTRATION For warranty information and registration visit: www.1paramount.com/products/warranty.