MDX DEBRIS REMOVAL SYSTEM MANUAL
FIBERGLASS LOW FLANGE POOLS
(UNITED STATES)
U.S. Patent No.: 6,810,537, 7,089,607, 7,178,179
ASME/ANSI A112.19.8M—1987 LISTED
Notice to Installers:
Read and follow these instructions. Give these instructions to
the facility owner. Follow all codes and regulations that apply to
the design, installation and use of suction outlet fittings.
MDX0844
004-027-8760-00
2/07
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
T oll Free: 1.800 . 621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
paramount@1Paramount.com • www.1Paramount.com
1

Advertisement

loading

Summary of Contents for Paramount Fitness MDX

  • Page 1 MDX DEBRIS REMOVAL SYSTEM MANUAL FIBERGLASS LOW FLANGE POOLS (UNITED STATES) U.S. Patent No.: 6,810,537, 7,089,607, 7,178,179 ASME/ANSI A112.19.8M—1987 LISTED Notice to Installers: Read and follow these instructions. Give these instructions to the facility owner. Follow all codes and regulations that apply to the design, installation and use of suction outlet fittings.
  • Page 2 The MDX Debris Removal System is only available to certified contractors for the same reason certified electricians are required to connect filtration pumps to public utilities; both require proper training and certification to assure no hidden hazards are built into the project.
  • Page 3 Maximum Pump Size: MDX is rated for a maximum of 90 GPM. While system flow rate will vary with pump size and the Total Head Loss for a given system, virtually any modern pump is capable of exceeding this limit, therefore it is the responsibility of the system designer to make sure it is not possible to exceed 90 GPM.
  • Page 4 Secure seal ring and sump together with six (6) 12" x 1 1/2" flathead screws. Secure 2nd Suction Outlet fitting through sidewall in FIBERGLASS SHELL desired locations. Make plumbing connection between 2nd Suction Outlet and 2½" outlet on bottom of MDX Sump. Pipe must be equal to circulation line.
  • Page 5 FIBERGLASS INSTALLATION Select the installation location for the SDX drain. Fig. 3 Fiberglass (Additional SDX drain may be used.) Shell For Fiberglass Wall: Cut one 4½" hole using a 4 ½" hole saw. Install the SDX Bulkhead Fitting with the “UP” arrow located at the top.
  • Page 6 MDX Sump is equivalent to a 2" Threaded Female hydrostat is not used, plug this port. Do not install any Adapter and a 2" Slip Fitting Outside the MDX Sump. For suction equipment (pump) to this port! non-hydrostatic installations, install the 2" plug provided.
  • Page 7 MDX WINTERIZATION WITH CANISTER WITHOUT CANISTER If vacuum relief suction outlets are located below freeze If vacuum relief suction outlets are located below freeze line skip steps 1 and 2. line skip steps 1 and 2. Remove grate from second suction and install blow Remove grate from second suction and install blow through plug and blow line to achieve airlock.
  • Page 8 Item Part Number Description 005-252-0826-00 Screw: No. 10-7/8" Phillips Head (12 pk) 005-252-2080-XX MDX Cover (XX = Color Code) 005-252-1605-00 Plug 2" (6 pk) 005-252-0822-00 Screw: No. 10-1 7/8" Security Head (12 pk) 005-252-0834-00 Screw: 12 x 2-5/8" Security Head (12 pk)