RETROJET
INSTALLATION GUIDE
For replacing: A&A Quikclean1, A&A Quikclean2, A&A Quikclean Gamma 3,
Caretaker 99, Caretaker 99 Threaded, Net'N'Clean and Pool Valet
T M
UNIVERSAL IN-FLOOR NOZZLE REPLACEMENTS
1
Use removal tool made for exist-
ing nozzle to remove one nozzle
at a time by rotation 1/4 turn
counter clockwise to unlock.
The system is hydraulically bal-
anced, so the same size nozzle
needs to go back into the ap-
propriate hole.
www.1Paramount.com
For Caretaker 99
®
T M
For Caretaker 99 Threaded
®
T M
For A&A Quikclean 1
®
This installation guide walks you
through the steps involved in re-
moving an existing cleaning nozzle
and properly installing a new Ret-
T M
rojet.
For A&A Quikclean 2
®
For
technical
assistance
1.800.621.5886 or contact your
regional representative
2
T M
For A&A Gamma 3
®
T M
For Net'n'Clean
Check the size of the opening
on the existing nozzle and then
select the closest RetroJet cap
from the pack of three provid-
ed in the replacement kit.
1.800.621.5886
RETROJET
INSTALLATION GUIDE
For replacing: A&A Quikclean1, A&A Quikclean2, A&A Quikclean Gamma 3,
Caretaker 99, Caretaker 99 Threaded, Net'N'Clean and Pool Valet
call
UNIVERSAL IN-FLOOR NOZZLE REPLACEMENTS
1
Use removal tool made for exist-
ing nozzle to remove one nozzle
at a time by rotation 1/4 turn
counter clockwise to unlock.
The system is hydraulically bal-
anced, so the same size nozzle
needs to go back into the ap-
propriate hole.
www.1Paramount.com
This installation guide walks you
through the steps involved in re-
moving an existing cleaning nozzle
and properly installing a new Ret-
rojet.
T M
For
technical
assistance
1.800.621.5886 or contact your
regional representative
2
Check the size of the opening
on the existing nozzle and then
select the closest RetroJet cap
from the pack of three provid-
ed in the replacement kit.
1.800.621.5886
call