Notice to Installers:
Read and follow these instructions. Give these instructions to the facility owner. Follow all codes
and regulations that apply to the design, installation and use of suction outlet fittings.
VAN0689
004-027-8720-00
REV040111
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800 . 621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com

Advertisement

Table of Contents
loading

Summary of Contents for Paramount Fitness VANTAGE IN-FLOOR CLEANING SYSTEM

  • Page 1 UTOM TIC IN-FLOOR CLE NING & CIRCUL TING SYSTEM INSTALLATION MANUAL MADE IN USA U.S. Patent No.: 4,114,206 4,592,379 4,939,797 5,135,579 5,251,343 5,265,631 6,301,723 6,311,728 6,314,999 6,360,767 6,367,098 6,393,629 6,601,244 6,810,537 7,089,607 D,532,684 D,531,888 7,178,179 Other Patents Pending Canada patents 2,028,766 Notice to Installers: Read and follow these instructions.
  • Page 2 FORW RD The Paramount VANTAGE IN-FLOOR CLEANING SYSTEM is the culmination of years of extensive testing and engineering which provides your customers with the most advanced and trouble-free system available. The information contained in this manual is intended to answer some of the most common questions associated with the installation of the System.
  • Page 3: Table Of Contents

    T BLE OF CONTENTS V NT GE L YOUT & DESIGN ..........2-4 DEBRIS DR IN INST LL TION .
  • Page 4: Nt Ge L Yout & Design

    PLUMBING DI GR M DRAWING FIXED DEBRIS DRAIN CANISTER CIRCULATION/CLEANING SYSTEM FIXED NOZZLES PUMP G.P.M. @ HD DEBRIS DRAIN AND SDX MUST BE INSTALLED ROTATING NOZZLES MIN.FILTER 5STEP 1STEP IN ACCORDANCE WITH PARAMOUNTS STEP NOZZLES CART. WRITTEN INSTRUCTION MANUAL, AND IN 6-PORT VALVE D.E.
  • Page 5 V NT GE, V NT GE PLUS & V NT GE ULTIM TE: The Vantage System for pre-formed composite pools is a specialized variation on the Paramount PCC 2000, which is the most advanced In-Floor Cleaning and Circulation system available for swimming pools in the world today.
  • Page 6: Debris Dr In Inst Ll Tion

    V NT GE, V NT GE PLUS & V NT GE ULTIM TE: Port Sequencing Port 2 Port 3 Port 1 Port 4 Port 5 Port 6 Fixed Head Debris Drain Note: Plumbed to Optional Fixed head is NOT Debris Canister plumbed into water valve 2 1/2”...
  • Page 7: Pre Plumbing/V Nt Ge Floor Nd Step He D Inst Ll Tion

    V NT GE INST LL TION BODY INST LL TION TO SHELL BEFORE SETTING POOL FIG 1 Floor Head Installation Remove the red construction cap from the top of the black body socket. FIG. 1 FIG 2 ttaching the colored trim ring. lways install the trim ring first to ensure proper alignment of the nozzle to the pool floor.
  • Page 8 V NT GE INST LL TION V NT GE INST LL TION BODY INST LL TION TO SHELL BEFORE SETTING POOL (continued) Primer and glue (using a slow drying glue FIG 5 Weldon IPS 705 or 711) the flange on the bottom of the floor body supplied in the kit, working glue into the recessed chamber on the outside of...
  • Page 9 V NT GE INST LL TION BODY INST LL TION TO SHELL BEFORE SETTING POOL (continued) FIG 7 FIG 7 shows a cross section of the floor nozzle in the Vantage body with the 2 ⁄ ” x 2” 90° ell glued into the body. NOTE: V NT GE FLOOR NOZZLES INST LL COUNTER CLOCKWISE ND COME OUT CLOCKWISE.
  • Page 10 INST LL TION PRE-PLUMB STEP ND FLOOR NOZZLES UP W LL BEFORE SETTING POOL FOOTNOTES ON STEP M NIFOLD PLUMBING When plumbing step manifolds that include Bench nozzles, follow the procedure pictured including the bench nozzles in the manifold. Place the 2”...
  • Page 11: Debris C Nister Inst Ll Tion

    INST LL TION Debris Canister: The Debris Canister must be set in the pool deck, as close to the pool as practical and be fitted with an unimpeded 1-1/2" Balance Pipe (also called an "Equalizer Pipe") between the Pool and the Canister. This is to permit pool water to flood the lid of the Canister.
  • Page 12: Numbering The W Ter V Lve Ports

    INST LL TION Pipe Grade & Size: Use 2" sch40 pipe throughout the Vantage system plumbing including connections to the Water Valve. It is permissible to use 1-1/2" sch40 pipe to join the step and seat heads together. The pipe run from the Water Valve to the first Tee must be 2". Try to minimize pipe runs and use of 90°...
  • Page 13: Loc Tion Of W Ter V Lve & Nd Pipe Gr De & Size

    INST LL TION 2" V LVE B SE PLUMBING GUIDE NOTICE: All pipe fittings MUST be staggered. (See pictures on page 21) All plumbing should be 2". The water valve is normally set 6" above water level in a convenient location poolside. This results in dramatic reduction in plumbing runs and increased cost savings.
  • Page 14 INST LL TION V LVE FOR 5-PORT SYSTEM SIDE VIEW TOP VIEW 5-PORT SYSTEM, ZONES 1 ND 3 RE TIED TOGETHER Gluing Instructions Remove Clamp Allow 24 hour before pressure testing. Lift off dome (save 0-ring) Reposition o-ring in groove in the valve base. Remove pressure gauge and T-handle from inside valve Replace dome and V-Clamp and tighten until snug.
  • Page 15 INST LL TION Plumbing (Equipment) 2" V LVE B SE PLUMBING GUIDE NOTICE: All pipe fittings MUST be staggered. P RTS NEEDED FOR SSEMBLY OPTION ONE • (3) 2"X12" PVC PIPE (port 2,4,6) • (3) 2"X15" PVC PIPE (port 1,3,5) •...
  • Page 16: Uxili Ry Equipment Connections

    UXILI RY EQUIPMENT CONNECTIONS Suction from Pool: For safety and to fine tune the system, the pump driving the Water Valve must have suction lines from both the Skimmer and the Debris canister (&/or Active Drain). Additionally, these suction lines must each have a Two-Way valve in-line or a Three-Way Valve to permit correct adjustment to the suction flow.
  • Page 17: Pump Inst Ll Tion

    PUMP INST LL TION One Pump Systems: Single Pump System The pump must be a high head pump capable of 60 gpm at 70 ft. of head and the filter should be a mini- mum of a 4.9 sand filter with a two inch valve, 36 sq. ft.
  • Page 18: St Rt-Up

    ST RT UP General Observations Concerning Water Valve and Nozzles: As a rule, do not install the module until after filling the pool and running the pump for at least ten minutes. After installing the module run the valve for several cycles to clear the plumbing runs to the pool of debris. Install the nozzles from poolside with the Nozzle installation tool.
  • Page 19: Winteriz Tion

    WINTERIZING INSTRUCTIONS Winterizing a Paramount Pool & Spa Systems in-floor pool is the same as any pool with a main drain; it just has a few more lines to winterize. These procedures are to be used in addition to standard winterization methods normally used in your area. To Do List: Store the Paramount valve module, canister inner lid and basket in a safe, dry place.
  • Page 20 WINTERIZING INSTRUCTIONS ( Cont. ) W TER V LVE NOTE: 1 1/2 and 2 inch test plugs with Schrader valves are available through your pool store or local wholesaler. The Special trapezoid plug with Schrader valve is available through Paramount Part number 004-302-1670-00. These are the test plugs referred to in Step #6 and Figures 4 and 5 (and only fit 2”...
  • Page 21: Trouble-Shooting

    TROUBLE SHOOTING Typical Mistakes Made During Installation and Orientation: The following are mistakes occasionally occur. Fortunately, they are rare when well-trained, experienced, conscientious installers have carried out the installation! • Allowing dirt and debris to get into the pipe work during construction •...
  • Page 22 TROUBLE SHOOTING DIRTY SPOTS IN POOL: Check that there is sufficient pressure at the Water Valve (20-25 psi). Note that the pressure at the valve not the filter is important here! If not then the cause of the low pressure must be established first. Possible causes of the low pressure include: •...
  • Page 23 TROUBLE SHOOTING PRESSURE INCRE SE T FILTER: • Clean the filter • Clean all baskets - skimmer, debris canister, pump • Check all ancillary valves are adjusted correctly NOZZLE POPS UP BUT DOES NOT ROT TE: • Push the nozzle up and down (with water pressure directed to that nozzle) to dislodge any debris •...
  • Page 24 TROUBLE SHOOTING LE KING W TER V LVE: • Lid incorrectly fitted - remove, clean thoroughly and replace correctly. • Leaking Run/Pause control - generally only requires tightening, occasionally needs new seal. • Damaged "O" ring (very rare) - remove and replace. •...
  • Page 25: Bill Of M Teri Ls

    BILL OF M TERI LS Part Number Diagrams Top Dome Complete: 005-302-4300-03 (Includes: Top, Gauge & Pause Assembly) Pause Assembly: 005-302-3502-00 (Includes: Screw, Knob, O-Ring & Pawl) 6 Port Module Complete: 004-302-4408-00 Band Clamp Complete: 005-302-3570-00 (Includes: Clamp, Nut, & Knob) Band Clamp Nut Only: 005-302-0640-00 Band Clamp Knob Only: 005-302-3600-00 Valve O-Ring Only: 005-302-0100-00...
  • Page 26 BILL OF M TERI LS ITEM P RT NO. DESCRIPTION Vantage Escutcheon Vantage Retainer closure Vantage Main retainer CCH Vantage Nozzle stem Vantage Dowel Pin 005-602-0142-00 Vantage Nozzle O-ring 2-138 silicone (4 pcs) Vantage Rotating thrust washer Vantage Fixed thrust washer Vantage Rotating head spring 005-602-5600-00 Vantage Nozzle Jet Inserts 1/8”...
  • Page 27 BILL OF M TERI LS NOZZLE & BODY DI GR M ITEM P RT NO. DESCRIPTION 006-602-6052-XX Vantage Step Single Head Kit (XX=Color Code) Vantage Trim Ring (XX=Color Code) Vantage Step Body Vantage Step Nozzle Caps (3pcs) (XX=Color Code) Vantage Step Nozzle Retainer O-ring 2-138 silicone (4 pcs) Vantage Nozzle (with caps) (XX=Color Code) NOT AVAILABLE FOR PURCHASE SEPARATELY...

Table of Contents