Panasonic AJ-D92P Operating Instructions Manual page 55

Dvcpro 50 digital video cassette recorder
Table of Contents

Advertisement

Error Messages
Error code
E — 65
E — 66
E — 67
E — 68
E — 69
E — 6B
E — 80
E — 90
E — A0
E — bA
Warning display
SLACK
This appears when abnormal tension has been detected.
This appears when the start or end processing operation fails to be completed within 7
SLACK
seconds.
This appears when there is a communication error between SERVO and AVSYS.
SLACK
There is a problem with the data.
This appears when there is a communication error between SERVO and AVSYS.
SLACK
The data is fixed to High or Low.
This appears when there is a problem in communication between SERVO and AVSYS
SLACK
when the power is turned on.
This appears when there is a communication error between IF and AVSYS.
No display
There is a problem with the internal reference or external reference.
No display
This appears when there is a problem with the supply voltage.
No display
This appears when the backup battery has totally discharged.
This appears when there is no input of video signals or when video signals are cut off
No display
and the mismatching detector circuit has been activated.
(The [E-A0] and the time data will be displayed alternately in the REC PAUSE mode.)
This appears when the input DC voltage has dropped to near the undercut voltage level
BATT flashes
(approx. 10.6 V).
Description
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj-d92

Table of Contents