4. Trouble shooting.
How to check IPM
Forward : test 1 GND(+) , Sus-out(-)
2 Sus-out(+),Vs(-)
3 ER-DN(-),ER-COM(+)
4 ER-COM(-),ER-UP(+)
when each 4 TEST Diode value is over 0.4V => OK
Reverse : test 1 GND(-) , Sus-out(+)
2 Sus-out(-),Vs(+)
3 ER-DN(+),ER-COM(-)
4 ER-COM(+),ER-UP(-)
when each 4 nodes TEST Diode value is infinity => OK
※ Specially, the value of ER-UP,COM,DN in the Y/Z board, should be
checked all of them. but, the terminal of Vs,Sus-out,GND,
we must aware to know after check one of IPM because it is parallel.
if no problems, check 15V(Y,Z B/D) with GND,
Reverse value infinite. If no problems,
40 /40
Forward value 0.3V,