d&b audiotechnik Ti10 Manual
Hide thumbs Also See for Ti10:

Advertisement

Quick Links

Ti10
Manual 1.1 en

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ti10 and is the answer not in the manual?

Questions and answers

Summary of Contents for d&b audiotechnik Ti10

  • Page 1 Ti10 Manual 1.1 en...
  • Page 2: Table Of Contents

    EU conformity of loudspeakers (CE symbol)........10 WEEE Declaration (Disposal)...............10 General Information Ti10 Manual Version 1.1 en, 03/2016, D2602.EN .01 Copyright © 2016 by d&b audiotechnik GmbH; all rights reserved. Keep this manual with the product or in a safe place so that it is available for future reference.
  • Page 3: Safety Precautions

    Generally speaking, a distance of 0.5 m (1.5 ft) from magnetic data carriers (floppy disks, audio and video tapes, bank cards, etc.) is sufficient; a distance of more than 1 m (3 ft) may be necessary with computer and video monitors. Ti10 Manual (1.1 en) Safety precautions - 1...
  • Page 4: Ti10

    Ti10 The Ti10 is the installation version of the T10 loudspeaker. It is a very compact loudspeaker system which can be used both as a line array and as a high directivity point source speaker. For these applications the Ti10 cabinet provides two different dispersion characteristics which can be swapped over without any tools.
  • Page 5: Ti10L, Ti10P Cabinet Options

    - Provide an additional cover over the loudspeakers. - Aim the cabinets either horizontally or with a downward tilt. Ti10 Manual (1.1 en) Page 5 of 10...
  • Page 6: Connections

    Connections The Ti10 cabinet is fitted with a pair of NL4 connectors. All pins of both connectors are wired in parallel. The Ti10 uses the pin assignments 1+/ 1–. Pins 2+/2– are designated to active subwoofers. Using one passive crossover connector as the input, the second connector allows for direct connection to additional loudspeakers.
  • Page 7 For acoustic adjustment the functions CUT, HFA, HFC and CPL can be selected. CUT circuit Set to CUT, the Ti10 low frequency level is reduced. The Ti10 is now configured for use with the Ti-SUB or other d&b active subwoofers. HFA circuit (T10 PS setup only) In HFA mode (High Frequency Attenuation), the HF response of the Ti10 system is rolled off.
  • Page 8: Dispersion Characteristics

    Dispersion characteristics The graphs below show dispersion angle over frequency of a single Ti10 cabinet plotted using lines of equal sound pressure (isobars) at – 6 dB and –12 dB. Fig. 9: Isobar diagram Ti10 line source, horizontal Fig. 10: Isobar diagram Ti10 line source, vertical Fig.
  • Page 9: Technical Specifications

    D80/D20/D12/30D................130 dB (SPLmax peak, pink noise test signal with crest factor of 4) Input level (100 dB-SPL/1 m)................–13 dBu Ti10L/P loudspeaker Fig. 13: Ti10 frequency response line source, single cabinet, Nominal impedance..................16 ohms standard and CUT settings Power handling capacity (RMS / peak 10 ms)........200/800 W Nominal dispersion angle (point source, hor.
  • Page 10: Manufacturer's Declarations

    Manufacturer's Declarations EU conformity of loudspeakers (CE symbol) This declaration applies to Ti10L loudspeaker, Z0551 Ti10P loudspeaker, Z0552 manufactured by d&b audiotechnik GmbH. All production versions of these types are included, provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications.

Table of Contents