Eiki LC-XB200A Service Manual page 48

Hide thumbs Also See for LC-XB200A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
Group
auto calibration (Ycbcr)
264
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
CB - OFFSET AREA H
2
START
3 CB - OFFSET AREA V START CB - Offset Acquiring Area V-Start
4 CR - OFFSET AREA H
START
5 CR - OFFSET AREA V START CR - Offset Acquiring Area V-Start
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
8 CB - GAIN AREA H START
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
12 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y-GAIN TARGET
18 CB-GAINTARGET
19 CR-GAINTARGET
20 OFFSET torelance
21 GAIN torelance
Group
cuStoM(aspect)
270
0 Scaler Horizontal
1 Sclaler Vertical
2 Connect
3 Position Horizontal
4 Position Vertical
5 Aspect Enable
Group
autoPc adjust
280
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group
Paneltype * Panel type check
290
0 GammaL/R-View
1 GammaL/R-Change
Group
composite (NtSc) composite / S-Video
500
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group
composite (PaL) composite / S-Video
501
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
Function
Y - Offset Acquiring Area H-Start
Position
Y - Offset Acquiring Area V-Start
Position
CB - Offset Acquiring Area H-Start
Position
Position
CR - Offset Acquiring Area H-Start
Position
Position
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Horizontal Scaler Edit
Vertical Scaler Edit
Seperate/Connect Edit
Horizontal Postion Correction
Vertical Position Correct
Aspect Adj. Enable
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of Total Dot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
Initial
925
500
925
500
925
500
50
500
800
500
700
500
13
9
4
128
128
217
237
237
1
1
100
100
0
100
100
0
0
1
5
1
1
0
0
10
668
28
18
458
658
34
22
-48-
range
Note
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0-255
0-255
0-255
0-255
1-255
1-255
68-132
68-132
0-1
0:Seperate, 1: Connect
85-115
85-115
0-1
1: Enable, 0: Disable
0-1
0:Enabel, 1:Disable
0-3
0-10
0[]<-- - --> 10[Not matched]
0-1
0;Excutes Fine Phase; 1:Not Excute
0 - 3
0: Effective All Bit,
1: Disable Lower 1 bit
0 - 3
2: Disable Lower 2 bit, 3: Disable
Lower 3 bit
0: Gamma for L-Turn
0-20
20: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is
set to 0.
0-20
Sets R-Turn Gamma if the Value is
set to 20.
0 �� 4095
0 �� 4095
0 �� 4095
0 �� 4095
0 �� 4095
0 �� 4095
0 �� 4095

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-xb100a