Eiki LC-XB200A Service Manual page 46

Hide thumbs Also See for LC-XB200A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset
(Temp)
16 Temp B Warning Offset
(Temp)
17 Temp C Warning Offset
(Temp)
18 Temp B-A Warning Offset
(Temp)
19 Temp C-A Warning Offset
(Temp)
Temp A Warning Offset
20
(Time)
Temp B Warning Offset
21
(Time)
22 Temp C Warning Offset
(Time)
Temp B-A Warning Offset
23
(Time)
Temp C-A Warning Offset
24
(Time)
Group
Fan control range Setting (temp./Voltage)
254
10 Normal Fan Control Min Temp
Normal Fan Control Max
11
Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Fan3 Cooling Spees
8 Cooling Time L1
9 Cooling Time L2
10 Temp Error Cooling Time
11 OnStart Cooling Start Thresh-
old
12 After shutdown cooling
Group
Fan Lamp Voltage down Setting
256
0 Lamp Voltage
Function
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L2 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Initial
100
100
100
100
44
44
43
44
60
60
60
60
60
60
63
60
100
100
100
100
100
100
100
100
5
5
5
0
0
3
3
3
3
3
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
33
33
35
35
38
38
39
39
50
55
85
85
115
120
125
125
45
45
60
60
50
50
62
62
80
85
90
90
125
125
125
125
30
30
35
35
38
38
39
39
50
55
85
85
115
120
125
125
45
45
60
60
50
50
62
62
70
75
90
95
125
125
125
125
55
55
55
130
130
130
2
3
3
38
1
-
-46-
range
Note
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15
1-15
0-100
0-1
0-255